PROGRAMMING PROCEDURE (parameter setting)
• All the functions of the electronic programmer can be set in the Display menu "LCD1" using the three buttons contained therein:
- use the arrows to navigate through the menu and/or to adjust the display contrast;
- use "PROG/OK" to modify the parameter settings and/or to confirm.
T B
F I
PROGRAM
F S
CP
T B
F I
00.000.001
F S
CP
FW_1.0
"PROG/OK" to confirm
SEQUENTIAL COM.
OPEN-STOP-SHUT
"PROG/OK" to set
AUTO-RECLOSING
"PROG/OK" to set
PRE-FLASHING
"PROG/OK" to set
WARNING LIGHTS
INTERMITTENT
"PROG/OK" to set
INDICATOR LIGHT
INTERMITTENT
"PROG/OK" to set
PHOTOCELL INVERT
DURING CLOSING/
"PROG/OK" to set
"PROG/OK" to set
"PROG/OK" to set
INSTALLED MOTOR
"PROG/OK" to set
MEMO RADIO
"PROG/OK" to set
ELECTRIC LOCK
"PROG/OK" to set
"PROG/OK" to confirm
BACK TO OPTIONS
5) Current sensor settings:
- Level 1 = motor electrical input + 2 amps - Level 2 = motor electrical input + 2.5 amps
- Level 3 = motor electrical input + 3 amps - Level 4 = motor electrical input + 4 amps
- Level 5 = motor electrical input + 5 amps
The programmer checks the electrical input to the motor, detecting any eventual increase in effort above the normal operating limits and intervenes as an
additional safety device.
6) Setting the distance from the closing/opening travel limit:
To increase or reduce this distance modify the parameter in steps from 0 to 9 (range fro 0 to 6 cm ~). By default the appliance is set to level 4 and in this
way the gate will not slam against the travel limits but will stop within a centimetre of them.
OPTIONS
SAFETY DEVICES
OK
"PROG/OK" to confirm
TB CONTACT
OPEN-SHUT/
"PROG/OK" to set
ON/OFF
"PROG/OK" to set
FS CONTACT
ON/OFF
"PROG/OK" to set
CP CONTACT
FIXED/
"PROG/OK" to set
(1)
FIXED/
"PROG/OK" to confirm
BACK TO SAFETY DEVICES
(2)
AND IN STOP
(3)
TEST FI
ON/OFF
(3)
TEST FS
ON/OFF
LEFT/RIGHT
Note:
1) The indicator light flashes slowly during opening, rapidly during closing; remains lit when
the gate is blocked but not completely closed and is off when the gate is completely closed.
2) FI Mode:
- FI also active when the gate is blocked: If the photocells are in alarm and the gate is blocked, no
ON/OFF
movement commands will be accepted (even opening commands);
- FI active only during closing
In both cases activating the FI safety device during the closing stage will force travel direction
inversion.
ON/OFF
3) Photocell test (FI/FS)
If you enable the security test you will have to connect both the transmitter and the receiver to the
controlled load output (CTRL 24 Vdc). When the test is enabled one second will pass between
receiving a command and carrying it out.
EXIT
OK
4)
Value
1
2
3
OK
"PROG/OK" to confirm
TORQUE SELECTION
NC/8K2
"PROG/OK" to set
FI CONTACT
CURRENT SENSOR
NC/8K2
"PROG/OK" to set
LIMITED OPENING
NC/8K2
"PROG/OK" to set
DIST. FROM CLOSE
NC/8K2
"PROG/OK" to set
EXIT
DIST. FROM OPEN
OK
"PROG/OK" to set
PAUSE TIME:
"PROG/OK" to set
RESET PARAMETERS
"PROG/OK" to set
"PROG/OK" to confirm
BACK TO MOTION MENU
Torque at
Torque at
Value
slow speed
top speed
slow speed
25%
75%
4
25%
100%
5
36%
75%
6
18
MOTION
OK
"PROG/OK" to confirm
(4)
LEVELS 1...6
"PROG/OK" to set
(5)
ADJUST CONTRAST
LEVELS 1...5
"PROG/OK" to confirm
REAR LIGHTING
1...9 meters
60 SEC./30 SEC.
"PROG/OK" to set
(6)
0...9 steps
"PROG/OK" to confirm
BACK TO DISPLAY MENU
(6)
0...9 steps
Press the arrows to increase or
reduce the value (max 240 seconds).
30
Keep the arrow keys pressed to scroll
OK
the value rapidly.
Press OK to reset the parameters to the
factory default settings (excluding the
number of manouvres). Press EXIT
OK
to quit without modifying the parameters
EXIT
OK
Torque at
Torque at
top speed
36%
100%
60%
75%
60%
100%
DISPLAY
OK
CONTRAST
OK
0...63
ALWAYS ON/
EXIT
OK