design and present a flow cross-section, when open, equal to that of the
pipeline. During normal operation, all valves installed (apart from the
drain valves) must be in the fully open position.
If the Spa-pack purchased is a type "with heat exchanger", the primary
water circuit of the exchanger must also be connected to a boiler (see
HEAT EXCHANGER CONNECTIONS - fig 14).
The Spa-pack must always be installed in an enclosed but ventilated
space, inaccessible except with keys or special tools, and protected
from water and weather.
The temperature in the enclosure housing the Spa-pack must not
exceed 40 °C, otherwise the pumps may not cool properly and the
integrity of the electronic control equipment could be affected.
Overflow tank
The tank must be installed near to the minipool and positioned at least
40 cm lower, but no more than 2 metres lower.
In the event of the overflow tank being installed outdoors, prevent any
risk of damage by adopting a system to ensure protection from direct
sunlight, ultraviolet radiation and extreme weather conditions.
If the pool is to be used in winter, it may be advisable to lag the overflow
tank with a suitable insulation material.
7
PLACEMENT
Move the minipool into its final position, with the plumbing fittings
directed toward the channel carrying the pipelines away from the pit.
Refit the legs and feet.
8
LEVELLING THE MINIPOOL
Set the pool perfectly level by adjusting the feet. Fix the feet to the floor
with the screws and masonry plugs provided.
9
FITTING THE HANDRAIL
Drill the fixing centres in the floor, keeping to the distances indicated in
the drawing.
The screws (not supplied) should be steel, size M8x100, driven into
masonry plugs.
10
FITTING THE CANVAS
Position the canvas on the minipool. Secure suitable anchorages
(not supplied) to the deck, aligned with the straps.
The canvas is not intended to carry weights.
Do not sit, step or lie on the canvas.
Do not place objects on the canvas.
The canvas can be dangerous if not secured or properly closed.
Failure to follow the instructions for securing the canvas can result
in danger to the user.
Remove the canvas completely before stepping into the pool,
otherwise there is a risk of being trapped.
11
11
12
12
A
B
A
B

PLUMBING CONNECTIONS

The contractor will supply all the plumbing material (including fittings,
ball valves, etc.), needed to connect the minipool to the Spa-pack and to
the overflow tank, and must install suitably proportioned gullies,
inspectable and accessible for cleaning purposes, into which the drain
pipelines will be directed.
DRAIN: the contractor must install a Tee and a relative valve on the
pipeline connecting the outlet side of the filtration pump to the pool.
The drain line to the gully C can take the form of a hose connected to
the valve on the Tee, or alternatively, a permanent drain line can be
installed.
In particularly cold climates, where there is a risk of residual water
freezing in pipelines, it is advisable to install drain valves at
strategic points on the various circuits, so that the system can be
emptied completely.
The drain line (17) from the overflow tank must be connected to a gully
C, as also must the line from the overflow (13) of the tank.
In this instance, regulations state that the connection must be "vented",
for example incorporating an "air-break" so that there can be no reflux
back into the circuit after water has been displaced from the pool during
normal use.
Where a sand filter is installed, the plumbing connections to the Spa-
pack must also include a connection between the backwash valve (W)
and the drain gully C.
IMPORTANT: before making any permanent connection to the main
drain, contact the local authorities to check on regulations
governing the disposal of chemically treated water.
FILLING: the recommended method of filling the Teuco 630 is to use an
ordinary hose, taking care not to immerse the end as this could allow
reflux of water back into the main (3).
IMPORTANT: the solenoid valve (14) supplied with the pool must
be connected to the cold water supply and to the overflow tank by
the contractor, who will select the most convenient location
compatible with the length of the power cable.
The "air-break" device (16) supplied with the pool must be installed
on the overflow tank.
IMPORTANT: if the intention is to connect the minipool
permanently to the water supply, suitable non-return devices must
be incorporated to prevent reflux back to the water main.
Contact the local authorities before proceeding with this type of
installation.