RIB T2 Serie Importantes Instrucciones De Seguridad Para La Instalación página 27

Ocultar thumbs Ver también para T2 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

OPTIONALS -
For the connections and the technical data of the fixtures follow the relevant handbooks.
R
ADIO TRANSMITTER SUN
SUN 2CH
cod. ACG6052
SUN CLONE 2CH
cod. ACG6056
C
ODE LEARNIG SYSTEM RADIORECEIVERS
RX433/A
super eterodyne and coupling
RX433/A
super eterodyne and terminal board
RX433/A 2CH super eterodyne, 2 channel and coupling
RX433/A 2CH super eterodyne, 2 channel and terminal board
S
PARK
In order to make the systems mentioned above give the best performances, you need to
install an antenna tuned on the frequency of the radio receiver installed.
N.B. Pay attention to not let the central wire of the cable to came Into contact with
the external copper sheath, since this would prevent the antenna from working.
Install the antenna vertically and in such a way the remote control can reach it.
SPARK BLINKER WITH IN-BUILT INTERMITTENT CARD
LATERAL SUPPORT
SPARK ANTENNA 433
SUN 4CH
cod. ACG6054
SUN CLONE 4CH
cod. ACG6058
code ACG5055
code ACG5056
code ACG5051
code ACG5052
code ACG7059
code ACG7042
code ACG5452
F
IT SLIM
PHOTOCELLS for the wall-installation
PAIR OF COLUMNS FOR FIT SLIM
FIT SLIM photocells have synchronism function in AC current and ranges of 20 m.
You can fit many photocell couples close together thanks to the optional synchronizing
circuit SYNCRO TRANSMITTER TX SLIM SYNCRO code ACG8029 for more than 2
photocells couples (up to 4).
B
LOCK
KEY SELECTOR FOR WALL-INSTALLATION
KEY SELECTOR TO BUILD-IN
H
EATER ONLY FOR KING ICE
The in-built thermal sensor of the KING ICE motor can be connected to the terminal
block J7 on the T2 control board. For the connection details please refer to the KING ICE
Instruction Manual.
The probe for motor heating is a device intended to be used in extremely cold environment
(up to -30°C) to avoid motor freezing.
Such device activates automatically when the gate is steady (the position being irrelevant,
provided it is not moving) at a ambient temperature motor inferior to 10°C (found from the
sensor of temperature PROBE).
The work of the heater is indicated by both the DL6 and DL7 leds for the motor number
1, and by the DL4 and DL5 leds for the motor number 2.
When the motor is running the heating system is inoperative.
On elapsing of 10 seconds delay from gate stop, the heating system gets activated (in
case the environment temperature in the motor area is below 10°C).
Upon achieving a 20°C temperature the heating system deactivates, maintaining a
constant environment temperature.
TECHNICAL DATA
Operation voltage
5Vdc
Resistance
10K ±2% (at 25°C)
Working temperature
27
27
code ACG8032
code ACG8065
-30 ÷ +55°C
G
B
code ACG1053
code ACG1048

Publicidad

Tabla de contenido
loading

Tabla de contenido