BAT
(2x12V/1,2 Ah)
CHG
ADO01
10
General connections
ST1
ST2
COM
FT1
FT2
Display indications
M17C
R.E.
L: Line
N: Neutral
T: Earth
D1 and D2:
CL
(static)
Gate closed
CL
(flashing)
Gate closed
OP
(static)
Gate open
OP
(flashing)
Gate opening
PC
(flashing)
Pedestrian gate closing
PO
(static)
Pedestrian gate open
PO
(flashing)
Pedestrian gate opening
XX
(countdown)
Gate on standby
STOP
Actuator unlocked
PA
(static)
Pause (operation not complete)
rS
(flashing)
Gate searching for close position
D3 and D4:
C4
Opening safety device activated
C5
Closing safety device activated
E1
Encoder motor halted
F1
Force limit exceeded
bA
(static)
Battery working
bA
(flashing)
Battery voltage too low (the board
does not carry out any operations)
Ftço
Photocells defective (testing)
F: Main fuse
230VAC: 2,5A
125VAC: 4A
P71G