Breakdown
THERE IS WATER AROUND THE HEAT PUMP
When your heat pump is in heating mode, a large quantity of hot and
humid air goes through the evaporator and causes condensation.
It is normal to see this condensation running below your heat pump.
• To check if there is a possible leak, you must first deactivate the
heat pump and let the filtration pump operate for over five hours.
If there is still water running after this time, call your installer.
THE HEAT PUMP IS FUNCTIONINg WELL,
BUT DOES NOT MANAgE TO REACH
THE DESIRED TEMPERATURE
Sometimes, the heat loss caused by the external temperature is too great
to be compensated for only by the heat pump.
• Cover your pool as often as you can.
The evaporator may be dirty.
• Clean it.
Evaporation is done poorly due to inappropriate positioning of the heat
pump (see the "location" section on page 26 of this manual).
• The water output may be insufficient.
• Adjust it.
36