Installation instructions
Hydraulic connection diagram
All of the automatic chlorine distributor or electrolyser models must be
installed after the heat pump.
The filter must be located in front of the heat pump.
A "By-Pass" system must be installed on all of the systems to facilitate
maintenance of the equipment and, if necessary, to adjust the water
output going through the heat pump.
This output adjustment is compulsory when the installation output
exceeds 17 m
Fig.3
Exit
Pool
All the water goes into
Standard position for an
installation whose output is
less than 17 m
SETTINgS: PRESSOSWICH SENSITIVITY.
The circulation safety is ensured by a pressoswitch, it is set in the factory
but it may be necessary to adjust it in cases of specific installation con-
figurations. Adjustment of the pressoswitch is done inside the electric box
(reference point 17 page 38).
The necessity for adjustment may be motivated by an early release of this func-
tion when the heat pump is located far below the level of the pool.
28
/H
3
(see Fig. 3 for the "By Pass" setting)
Entry
Heat
pump.
Filter
"By-Pass"
closed
the heat pump
/H
3
Exit
Heat
pump.
Pool
"By-Pass"
open
Adjusting the water output
going through the heat pump.
Standard position for an instal-
lation whose output is greater
than or equal to 17 m
Entry
Filter
/H
3