Scope Of Delivery; Dimensions; Installation Example; Assembly Of Basic Installation Set - Franke PR3O0020 Instrucciones De Montaje Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

7.

Scope of delivery

Basic installation kit
Quantity
1
1
1
1
Installation kit
Quantity
1
1
1
1
2
1
1
1
8.

Dimensions

9.

Installation example

10. Assembly of basic installation set

Warning!
• Operate the product only with safety extra low voltage (SELV). The components
must not be earthed.
• Place the power supply (not part of the delivery , see accessories,
outside the wet area in a separate room.
• Protect the power supply with a residual current circuit breaker (RCD).
• Lay the system line (to be provided by the customer) in the empty pipe (to be
provided by the customer) from the power supply to the fittings and loop through.
Failure to observe this instruction can result in death or material damage due to
electric shock or fire, for example.
6
Name
Wall unit with lockable water quantity regulators
and flush connector
Electrical T-distributor with protective cap
Wall protection
Installation and operating instructions
Name
Cover plate with sensor module
Electronic module M3
Function block with thermostat mixer valve
Connection extension
Rosettes
Outlet
Plastic bag with filters and seals
Installation and operating instructions
Chapter
26)