Always mount the Vitapur
lamps. Service may require removing the UV lamp and quartz tube. A minimum distance equivalent
to the length of the UV reaction chamber (stainless steel cylinder) plus 6-12" (15-30cm) is required
to ensure adequate clearance. As the Vitapur
please ensure that no combustible items come into contact with, or are in proximity to the system. It
is recommended that you maintain at least 6" (15 cm) of clear wall space on all sides of the Vitapur
UV for cooling purposes. This will prolong the operating life of the system. Mount electronic controllers
where they will not get wet during maintenance or from condensation from copper pipes, etc.
I
I
nStallatIon
nStructIonS
To prevent contamination of water in the plumbing, which may pose a health hazard, do not
use the bypass line and valve if your source of supply is untreated surface water or groundwater.
If your source of supply is treated municipal water, use of the bypass line and valve will permit
uninterrupted treated water service in the event of a system malfunction. Always test the bypass
valve following each use of the bypass line, prior to re-starting the Vitapur
to confirm that the valve has been fully closed and that only water from the outlet port will be
going downstream. The installation of a drain valve, while not required for system operation, is
recommended for all installations of the Vitapur
valve will allow the service technician to drain the system of water prior to conducting any service
on the unit.
Recommended installation of the Vitapur
Water
Shut Off
Ground
Meter
Valve
Strap
Water Supply
Pro Series
Brine Tank
and Softener
Compteur
Vanne
Câble de
mise à la
d'eau
d'arrêt
* UV chamber should be mounted vertically (see figure on next page).
terre
* Union fittings are recommended in the event UV system needs to be removed from service.
Entrée d'eau
Bac à saumure
et adoucisseur
de série Pro
: a
cceSSIbIlIty
UV in a location that provides ample space for accessing the ultraviolet
®
: o
PtIonal
®
GFCI
Optional Bypass Valves
To
Drain
Sediment
Pre Filter
Disjoncteur de
fuite de terre
Vannes de dérivation optionnelles
, o
rIentatIon
UV disinfection system generates heat during use,
®
b
l
yPaSS
Ine and
UV disinfection system. The installation of a drain
®
UV disinfection system is as follows:
GFCI
Optional Carbon
Filter
Disjoncteur de
fuite de terre
& f
:
IttIngS
d
v
raIn
alve
UV disinfection system
®
Treated
Water
Exits
Electronic Control
Ballast
UV Chamber
10 GPM
10 G
Sortie
d'eau
traitée
Ballast de contrôle
électronique
®
:
P
R
O
Pro Series
Reverse Osmosis
Water Treatment
P
R
O

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Vuv-s645bVuv-h375bVuv-h645b

Tabla de contenido