9. Technical data

9.7 Volume/energy impulse open collector

Designation
Max. pulse frequency
Max. input voltage
Max. input current
Max. voltage drop at the
active output
Max. current through
inactive output
Max. reversed voltage without
destruction of the outputs
Min. pulse duration
Min. pulse interval

9.8 General

Designation
Limits for temporary
ambient temperature
(operating)
Limits for temporary
ambient temperature
(storage)
Rated pressure
Value
4 Hz
30 VDC
27 mA
2 V/27 mA
5 V/30 μA
6 V
125 ms
125 ms
Value
0 °C ... 55 °C
-20 °C ... 55 °C
16 bar