Description
A sewage system consists of a pump,
control switch, and a ba sin for use in
ap pli ca tions where less than six toilets
(units) are dis charged into the basin.
The sys tem is generally con trolled by a
float switch with a plug-in-plug which
accepts the pump plug and in turn
plugs into a 115 volt outlet.
The float switch is a wide angle
differential switch that rises with the
liquid level and turns the pump on.
As the liquid level decreases the float
lowers and turns the pump off. This
pump is in tend ed for use in do mes tic
sewage lift stations. It is suitable for
pumping sewage, effluent, wastewater,
groundwater and other non ex plo sive,
non cor ro sive liquids with up to 2 inch
solids.
Specifications
Power supply requirements .............. 115V, 60 hz
Circuit requirements .......................... 15 amps (min)
Motor duty ......................................... Intermittent
Motor ................................................. 115V, 1 Phase, 1725 RPM
Horsepower ....................................... 4/10 (SEL40); 1/2 (SEL50)
Motor full load .................................. 12 amps
Liquid temperature range ................. 40º F to 120º F
Max. operating position .................... 45º from vertical
Dimensions ......................................... 13-1/2 inch x 11 inch
Intake ................................................. 2 inch
Discharge ............................................ 2 inch NPT female, 3 inch
Cut-in level (factory set) .................... 18 inch
Cut-out level (factory set) ................. 10 inch
Differential ......................................... 8 inch
Switch ................................................. 90º wide angle
Power cord ......................................... 16 gauge 3 conductor
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2009 Wayne Water Systems
Sewage
Pump
unpacking
Inspect this unit before it is used.
Occasionally, products are damaged
during shipment. If the pump or
components are damaged, return
the unit to the place of purchase for
replacement. Failure to do so could
result in serious injury or death.
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
NPT male
mechanical tether switch
w/plug
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.waynepumps.com
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
information, that if not followed, may
cause damage to equipment.
General Safety Information
CALIfORNIA PROPOSItION 65
Danger indicates
an imminently
chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
Construction
Motor body material ............Cold rolled steel
Motor housing ......................Glass reinforced
Volute ....................................Glass reinforced ABS
Impeller .................................Glass reinforced PBT
Seal plate ..............................Cast Iron
Shaft seal ...............................End faced mechanical
Performance
GALLONS PER hOuR At tOtAL hEAD IN fEEt
Model
SEL40
SEL50
Models SEL40 and SEL50
Warning indicates
a potentially
Caution indicates
a potentially
Notice indicates
important
This product or its
power cord contains
polypropylene
10
15
3700
1350
6420
4200
330002-001 3/09
200
0
1500

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Wayne SEL40

  • Página 1 Motor duty ......... Intermittent Motor ..........115V, 1 Phase, 1725 RPM Volute ........Glass reinforced ABS Horsepower ........4/10 (SEL40); 1/2 (SEL50) Impeller .........Glass reinforced PBT Motor full load ........12 amps Seal plate ......Cast Iron Liquid temperature range ....40º F to 120º F Shaft seal .......End faced mechanical...
  • Página 2: General Safety

    Operating Instructions and Parts Manual General Safety Information 6. Check hoses for weak and worn 11. This equipment is only for use on condition before each use, making 120 volt (single-phase) and is (Continued) certain that all connections are equipped with an ap proved 3-con- GENERAL SAfEty secure.
  • Página 3 Models SEL40 and SEL50 General Safety Information valve in a horizontal position or at When a tether switch is used, rigid a 45º angle with the valve pivot on dis charge pipe is required. If the (Continued) top. In a vertical position, solids will...
  • Página 4: Troubleshooting Chart

    Operating Instructions and Parts Manual Maintenance (Continued) This pump contains dielectric motor 5. Submerge the complete pump in a oil for lubrication and motor heat disinfectant so lu tion (10% chlorine transfer. This oil can be harmful to the bleach solution) for at least one hour environment.
  • Página 5 Models SEL40 and SEL50 For replacement parts or technical assistance, call 1­800­237­0987 Please provide following information: Address parts correspondence to: - Model number Wayne Water Systems - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A.
  • Página 6: Service Record

    Limited Warranty For one year from the date of purchase, Wayne Water Systems ("Wayne") will repair or re place, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or work man ship.
  • Página 7 Moteur ..........115V, Monophasé, Volute ........ABS renforcé de verre 1725 tr/min Turbine ........PBT renforcé de verre Horse Power ........4/10 (SEL40) 1/2 (SEL50) Plaque d’étanchéité .....En fonte Moteur à pleine charge ..... 12 A Joint d’arbre ......Mécanique Gamme de température du liquide .. 4°C à 49°C (40º F à 120º F) Position de fonctionnement max.
  • Página 8 Instructions d‘Utilisation et Manual de Pièces Généralités Sur La Sécurité 6. Inspecter les tuyaux pour la faiblesse 11. Cet équipement est conçu pour un et l’usure avant chaque utilisation circuit de 120 v (monophasé) et est (Suite) et vérifier le serrage de tous les équipé...
  • Página 9 Modèles SEL40 et SEL50 Généralités Sur La Sécurité Installation Avant d’enlever la pompe du bassin (Suite) Utiliser un/des pour l’entretien, toujours couper système(s) de Le moteur de la puissance à la pompe et à sauvegarde là où il y a risque de la pompe est l’interrupteur de commande.
  • Página 10: Guide De Dépannage

    Instructions d‘Utilisation et Manual de Pièces Entretien (Suite) montage incorrect peuvent résulter au nettoyage. en hasard de secousse électrique. Enlever le couvercle du bassin Netttoyer toute saleté et dépots de et débrancher la tuyauterie de Situer la pompe dans un endroit l’arrivée de la pompe et la volute.
  • Página 11: Guide De Dépannage (Suite)

    Modèles SEL40 et SEL50 Guide de Dépannage (Suite) Symptôme Cause(s) Possible(s) Mesure Corrective La pompe 4. Pompe fonctionne à l’envers 4. Vérifier la rotation. (sens contraire des aiguilles d’une montre du bas) fonctionne mais Retourner si au sens des aiguilles d’une montre délivre peu ou...
  • Página 12 Garantie Limitée For one year from the date of purchase, Wayne Water Systems ("Wayne") will repair or re place, at its option, for the original purchase Pour un an à compter de la date d’achat, Wayne Water Systems (“Wayne”) vas réparer ou remplacer, à son option, pour l’acheteur originel n’importe quelle pièce ou pièces de ces Pompes De Puisard ou Pompes À...
  • Página 13: Descripción

    Ciclo del motor ......Intermitente Caja espiral ......Plástico ABS reforzado Motor ........... 115V, 1 fase, 1725 RPM con vidrio Caballos de fuerza ...... 4/10 (SEL40) 1/2 (SEL50) Impulsor ........Plástico PBT reforzado Motor (Cap. máx.) ....... 12 amperios con vidrio Temp.
  • Página 14 Manual de Instrucciones de Operación y Piezas Informaciones Generales de Antes de cada uso, inspeccione ¡Peligro las mangueras, para ver si están Seguridad (Continuación) de choque eléctrico! Nunca dañadas o desgastados y cerciórese GENERALES DE SEGuRIDAD conecte los cables verdes o de que las conexiones estén bien verde con rayas amarillas, a apretadas.
  • Página 15: Instalación

    Modelos SEL40 y SEL50 Informaciones Generales de Mantenimiento Enrosque la tubería de descarga o el niple en el orificio de descarga Seguridad (Continuación) Siempre desconecte de la unidad. 13. Es altamente recomendable que el cordón eléctrico Si usa una válvula de chequeo, en...
  • Página 16: Guía De Diagnóstico De Averías

    Manual de Instrucciones de Operación y Piezas Mantenimiento Coloque la bomba en un Limpie bien el orificio de entrada de sitio adecuado para limpiarla la bomba y la voluta. (Continuación) completamente. Quítele todos los Esta bomba Chequée la bomba periódicamente residuos e impurezas a la bomba.
  • Página 17: Modelos Sel40 Y Sel50

    Modelos SEL40 y SEL50 Guía de diagnóstico de averías (Continuación) Symptôme Cause(s) Possible(s) Mesure Corrective La bomba 4. La bomba está rotando en sentido 4. Chequée la rotación. (Sentido contrario al de las agujas del reloj al observarlo funciona pero...
  • Página 18: Registro De Servicios

    Garantía Limitada Durante un año a partir de la fecha de compra del comprador original, la compañía Wayne Water Systems ("Wayne") reparará o re emplazará, según lo decida, cualquier pieza de esta bomba de desagüe o bomba de agua que se encuentre defectuosa debido a materiales usados o procesos de manofactura.
  • Página 19 SEL40, SEL50 Notes / Notas / Notes...
  • Página 20 SEL40, SEL50 Operating Instructions and Parts Manual • Instructions d‘Utilisation et Manual de Pièces • Manual de Instrucciones de Operación y Piezas Notes / Notas / Notes...

Este manual también es adecuado para:

Sel50

Tabla de contenido