Please read and save these instructions. Read carefully before attempting to assemble, install,
operate or maintain the product described. Protect yourself and others by observing all safety
information. Failure to comply with instructions could result in personal injury and/or property
damage! Retain instructions for future reference.
Operating Instructions and Parts Manual
Description
The ESP15 and ESP25 are battery operated
back-up sump pump systems. It does
not replace a regular primary pump. It is
designed to provide protection in the event
household electrical power fails.
Unpacking
Inspect this unit before it is used.
Occasionally, products are damaged during
shipment. If the pump or components
are damaged, call our customer service
department at 1-800-237-0987.
Safety Guidelines
This manual contains information that is
very important to know and understand.
This information is provided for SAFETY
and to PREVENT EQUIPMENT PROBLEMS.
To help recognize this information,
observe the following symbols.
DANGER indicates
an imminently
hazardous situation which, if NOT avoided,
WILL result in death or serious injury.
WARNING indicates
a potentially
hazardous situation which, if NOT avoided,
COULD result in death or serious injury.
CAUTION indicates
a potentially
hazardous situation which, if NOT avoided,
MAY result in minor or moderate injury.
NOTICE indicates
important
information, that if NOT followed, MAY
cause damage to equipment.
General Safety Information
CALIFORNIA PROPOSITION 65
This product or its
power cord contains
chemicals known to the State of
California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
GENERAL SAFETY
Do NOT
use to
pump flammable or
explosive fluids such as
REMINDER: Keep your dated proof of purchase for warranty purposes!
© 2011, WAYNE/Scott Fetzer Company.
12V Battery
Back-up
Systems
gasoline, fuel oil, kerosene, etc. Do NOT
use in a flammable and/or explosive
atmosphere. Pump SHOULD only be
used to pump clear water. Personal
injury and/or property damage COULD
result.
qualified electrician. Failure to follow
this warning COULD result in fatal
electrical shock.
has water or moisture on the
floor, do NOT walk on wet
area until all power is turned
off. If the shutoff box is in the basement,
call an electrician. Remove pump and
either repair or replace. Failure to follow
this warning COULD result in fatal
electrical shock.
battery to sparks or flames as
an explosion or fire COULD
result.
corrosive. Avoid spilling on
skin or clothing. Eye
protection MUST be worn
when handling the battery.
sump pump discharge (see Figure 1).
clear water. This pump is NOT designed
to handle effluent, salt water, brine,
laundry discharge or any other
application which MAY contain caustic
chemicals and/or foreign materials.
Pump damage MAY occur if used in these
applications and WILL void warranty.
Battery Requirements
1.
Use only a new fully charged 12 V
deep cycle battery. Electrolyte level
must be checked and maintained
in accordance with manufacturer's
guidelines.
Attach it to this manual or file it for safekeeping.
For parts, product & service information
visit www.waynepumps.com
ESP15
2.
3.
All wiring MUST be
performed by a
If the
basement
Installation – ESP15
several hours. Before disabling your
main pump, have ready an appropriate
means of evacuating the sump.
Do NOT
1. Turn power to main pump off.
expose
2. Pump must be installed using 1-1/4
Battery
acid is
A check valve MUST be
used on the primary
A ground fault circuit
interrupter is required.
CHECK
This pump MUST only
VALVE
be used to pump
Figure 1
3. Measure and cut discharge pipe so
4. Check the fit of the components
ESP25
ESP15, ESP25
Battery sizes that will fit into the
battery box are 24C, 24VCM, 27C,
27CM, and 27F.
Battery recharge time will be
different at each installation. Under
normal conditions it will take two
to four days to bring a deep cycle
battery back to full charge after it
has been discharged. If electrical
power to the house is lost more
than once a week, consider keeping
a spare, fully-charged battery to
replace an exhausted battery for the
back-up sump pump.
Installation of this
unit may take
in. or 1-1/2 in. rigid PVC piping. A
check valve (not included) must be
installed between the ESP's tee and
the main pump (see Figure 1).
LEAVE A 4 IN.
MIN. BETWEEN
BASIN LID
LEAVE A 1 IN.
MIN. BETWEEN
BACK-UP AND
PRIMARY PUMP
that back-up pump is a minimum
of 1 in. above the main pump. This
will allow main pump to operate
normally (see Figure 1).
before permanently attaching. Using
PVC cement, glue tee in place. Note
the up direction arrow on the tee; the
notch must be to the top or flapper
valve will not work (see Figure 2).
354001-001 7/11
AND
BACK-UP
PUMP

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Wayne ESP15

  • Página 1 Battery sizes that will fit into the use in a flammable and/or explosive battery box are 24C, 24VCM, 27C, The ESP15 and ESP25 are battery operated atmosphere. Pump SHOULD only be 27CM, and 27F. back-up sump pump systems. It does used to pump clear water.
  • Página 2: Pump Installation

    Operating Instructions and Parts Manual hole, and secure with nut. Make sure Installation - ESP15 (continued) that float switch is above pump base 5. Insert flapper valve into tee. Be sure and that power wires do not interfere locator tab is in the notch of the tee with float switch or pump inlet.
  • Página 3: Control Box Installation

    NEVER cut off Control Box Installation – the round grounding prong. Cutting the ESP15 & ESP25 cord or plug will void the warranty and RIGID SLOPE make the pump inoperable.
  • Página 4 2. Obstruction in discharge pipe 2. Check for obstruction and clear if necessary 3. Pump not rotated 30˚ 3. Check that pump is rotated 30˚ in tee fitting in ESP15 Installation section, Figure 3, on page 2 4. Pump air locked 4.
  • Página 5 WAYNE Water Systems - Serial number (if any) 101 Production Drive - Part description and number as shown in parts list Harrison, OH 45030 U.S.A. Repair Parts List – ESP15 Repair Parts List – ESP25 Ref. Ref. Description Part Number...
  • Página 6 LIMITED WARRANTY System ESP15: For one (1) year from the date of purchase, WAYNE Water Systems ("WAYNE") will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by WAYNE to be defective in materials or workmanship.
  • Página 7: Systèmes De Secours Par Batterie De 12V

    être vérifié et entretenu selon et/ou explosif. La pompe devrait être les directives du fabricant. ESP15 et ESP25 sont des systèmes de pompe utilisée pour le pompage de l’eau claire La boîte de batterie accomode les seulement, sinon, il y a risque de blessures...
  • Página 8 Instructions d'Utilisation et Manual de Pièces Installation – ESP15 (suite) Pour installer l’interrupteur à flotteur po) ou 3,8 cm (1-1/2 po). Cimenter d’une pompe de secours, glisser un tuyau de 3,8 cm (1-1/2 po) à un Vérifier l’ajustage des pièces avant de raccord fileté.
  • Página 9 Coller un coude de 45º au tuyau l’équipement de perçage approprié. Sceller contrôle – ESP15 & ESP25 court de la pompe ESP25. Coller un le trou pour éviter que l’eau n’y pénètre. raccord en ‘Y’ au tuyau court sur la Fixer la boîte de contrôle au côté...
  • Página 10 2. Vérifier pour un engorgement et l’enlever si nécessaire pas d’eau 3. Pompe pas tournée à 30˚ 3. Vérifier que la pompe est tournée à 30˚ en montage T dans ESP15 Section Installation, Figure 3, à la page 10 4. Pompe bloquée à l’air 4.
  • Página 11 - Numéro de série (si applicable) 101 Production Drive - Description et numéro de pièce d’après la liste de pièces Harrison, OH 45030 U.S.A. Liste de Pièces Détachées – ESP15 Liste de Pièces Détachées – ESP25 No. de Numéro No. de Numéro...
  • Página 12: Garantie Limitée

    GARANTIE LIMITÉE Système ESP15: Pendant un (1) an à compter de la date d’achat, WAYNE Water Systems (WAYNE) va réparer ou remplacer, à sa discrétion, pour l’acheteur original n’importe quelle pièce ou pièces de ces Pompes de Puisard ou Pompes à eau (« Produit ») déterminées défectueuses, par WAYNE Water Systems, en termes de matériaux ou de fabrication.
  • Página 13: Sistemas De Respaldo De Batería De 12V

    Descripción Requisitos de la batería para GENERALES DE SEGURIDAD la bomba de respaldo NUNCA Los sistemas ESP15 y ESP25 son sistemas use esta de bombas de respaldo para sumideros 1. Use sólo baterías nuevas totalmente bomba para bombear líquidos operados con batería. No sustituye una cargadas de 12 V y ciclo intenso.
  • Página 14: Instalación De La Bomba

    Manual de Instrucciones de Operación y Piezas Instalación – ESP15 pozo del sumidero. No coloque la (Continuación) BOMBA bomba sobre una superficie blanda 3. Mida y corte el tubo de descarga de AUXILIAR PARA o arenosa. Las piedritas o la arena modo que la bomba auxiliar esté...
  • Página 15: Instalación De La Caja De Control - Esp15 Y Esp25

    CONTROL – ESP15 Y ESP25 contener una segunda bomba. adecuado. Selle el agujero para evitar 1. Conecte la caja de control a uno de 9.
  • Página 16: Funcionamiento

    3. La bomba no ha sido inclinada 30 grados 3. Verifique que la bomba se rote 30º en el conector en T en la sección de instalación de ESP15, Figura 3 en la página 18. 4. Bomba bloqueada por aire 4.
  • Página 17: Mantenimiento

    - Número de serie (si tiene) 101 Production Drive - Descripción y número de repuesto como se muestra en la lista de repuestos Harrison, OH 45030 U.S.A. Piezas de Repuestos – ESP15 Piezas de Repuestos – ESP25 N° de Número N°...
  • Página 18 Manual de Instrucciones de Operación y Piezas Notas 18 Sp...
  • Página 19 ESP15, ESP25 Notas 19 Sp...
  • Página 20: Garantía Limitada

    Y APTITUD PARA UN PROPÓSITO EN PARTICULAR, ESTÁN LIMITADAS A UNO (1) AÑO A PARTIR DE LA FECHA DE COMPRA PARA EL SISTEMA ESP15 Y A DOS (2) AÑOS A PARTIR DE LA FECHA DE COMPRA PARA EL SISTEMA ESP25.

Este manual también es adecuado para:

Esp25

Tabla de contenido