Balluff BIW1-A310 Serie Guia De Inicio Rapido página 5

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
BIW1-A/C/E/G310-M_ _ _ _-P1-S115
Micropulse Transducer in Profile Housing
Wiring
Pin
BIW1-A310...
Output signal:
2
0 V
5
0...10 V
Supply voltage:
6
7
Output slope:
1
4
Reserved leads must remain unconnected.
3
8
To have the output voltage rise
starting at the zero point, jumper
Pin 4 and Pin 1.
To have the output voltage fall
starting at the zero point, leave Pin
4 unconnected.
Once the slope has been selected
and applied and the slope
selection connections removed,
reselecting programs the BIW
again with the other slope. This
means the slope select connection
must remain in place so that it
stays the same even after the unit
is powered off multiple times.
Startup
Observe all relevant safety regula-
tions!
Check connections: Components
can be damaged by improper con-
nections and overvoltage. Verify all
connections before applying
power!
Turning on the system: Note that
the system may execute
uncontrolled movements when the
transducer is part of a closed-loop
system whose parameters have
not yet been set. Therefore make
sure that no hazards could result
from these situations.
BIW1-C310...
BIW1-E310...
0 V
0 V
0...20 mA
4...20 mA
GND
+24 V DC
Output slope -
Output slope +
Reserved
Reserved
System and control cabi-
net must be at the same
ground potential.
Note: The slope selection is not
applied until the unit is reset or
powered off/on.
Check functionality: The function-
ality of the transducer system and
all its associated components
should be regularly checked and
recorded.
Fault conditions: When there is
evidence that the transducer
system is not operating properly, it
should be taken out of service and
guarded against unauthorized use.
BIW1-G310...
0 V
-10...+10 V
Pin numbering for
connector, view of
BIW side
Cable
with connector
straight:
BKS-S115-PU-_ _
right-angle: BKS-S116-PU-_ _
Length: A/G < 25 m
not included
english
Cable BKS
GY gray
GN green
BU blue
BN brown
YE yellow
RD red
PK pink
WH white
5
4
6
3
7
8
2
1
C/E < 100 m
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Biw1-c310 serieBiw1-e310 serieBiw1-g310 serie

Tabla de contenido