The drive is stopped or the start-up is suppressed via this input.
G
- Connection for slip contact (accessory) or emergency stop.
3. Input STOP B
This input activates the automatic reversal of the drive during closing.
H
- Connection 4-wire photoelectric sensor
4. Power supply 24 V DC, max. 100 mA (switched)
I
- Connection for e.g. 24V signal light
5. Power supply 24 V DC, max. 100 mA (permanent)
I
- Connection for e.g. external receiver
Installation
+
-
- +