HeiTel Digital Video GmbH -  Quick Installation Guide CamServer 2c
Model alarm using
Aux in1
26
Testing the alarm
After  setting  the  device  parameters,  if  necessary  a  test  for  a  correct  alarm
should be carried out.
As an example, an alarm via the Aux
on page
19).
This contact, described as the tamper input, is particularly suitable for this,
because  an  alarm  is  given  regardless  of  the  arming/disarming  of  the
device. This input can be parameterised as a "Normally opened" contact
or a "Normally closed" contact (standard: normally opened).
Take the relevant transmission routes into operation.
Check  the  dial-up  number(s)  for  alarms: 
numbers (if necessary to your receiver PC or to the control station) (see
"Parameter settings for the device" on page
Ensure that the device is not in the alarm status.
Close the connection from Aux
for at least 500 ms.
Check to see whether the alarm is correctly sent to your receiver PC or to
the control station.
CamControl
LITE should report "Online/Tamper alarm" in the status line
bottom right in this case:
If the general alarm control input or camera-specific control inputs need to
be  checked,  ensure  without  fail  that  the  device  has  been  armed
beforehand.
in1 input is described (see "Aux in1"
Connections\Phone & IP
24).
in1 and to the relevant device ground 
CamServer 2c