Technical Data Sheet - Miele professional PG 8083 Plano De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6

Technical data sheet

Commercial dishwasher
Legend:
Electrical
1. Voltage (standard version)
connection
plug
plug
Variations in the following countries:
2. Voltage (standard version)
plug
plug
3. Voltage (standard version)
plug
plug
4. Voltage (standard version)
plug
plug
Installationsplan PG 8083
Stand: 15.09.2017
Circled, bold-type abbreviations:
Connection required
Abbreviations surrounded by broken circle:
Connection optional or required, depending on model
Power rating
Fuse rating
Connection cable, min. gauge
Connection cable length (H05(07)RN-F) without
Voltage
Power rating
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
Power rating
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
Voltage
Power rating
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
Power rating
Fuse rating
Connection cable, min. gauge
Connection cable length (H05(07)RN-F) without
Voltage
Power rating
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
Power rating
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
Voltage
Power rating
Fuse rating
Connection cable, min. gauge
Length of connection cable (H05(07)RN-F) with
PG 8083
GB
V/Hz
AC 230/50
kW
2,3
A
1 x 10
mm²
1,5
m
2,0
V/Hz
3 N AC 400/50
kW
8,3
A
3 × 16
mm²
2,5
m
1,7
V/Hz
AC 230/50
kW
6.7
A
1 x 32
mm²
4.0
m
2.3
V/Hz
AC 230/50
kW
2.3
A
1 x 13
mm²
1.5
m
2.2
V/Hz
3 AC 230/50
kW
6.7
A
3 x 20
mm²
2.5
m
1.7
V/Hz
AC 230/50
kW
2.3
A
1 x 10
mm²
1.5
m
2.0
V/Hz
AC 230/50
kW
5.3
A
1 x 25
mm²
2.5
m
1.9
V/Hz
AC 230/50
kW
2.3
A
1 x 10
mm²
1.5
m
1.8
4