Description • Functioning
Louvered fin position
Information regarding installation
Installation and replacement of the GLL10R filter
Installation and replacement of the GLL20R filter
Electric connections
Dip Switch Setting
Dimensions
DESCRIPTION
The FCL units are available in two fun-
damental dimensions, which will be
called:
"Module 600" for units that can be inte-
grated in the standard 600x600mm
suspended ceiling panelling.
"Module 840" for more powerful ver-
sions, dimensioned to be housed in a
compartment measuring 840x840mm.
INTAKE AND FLOW GRID UNIT
(GLL range accessories)
The FCL cassette type fan coil is only
completed if coupled to a GLL series
grid; a mandatory accessory for fan
coil functioning. The GLL series grid
accessories, as well as intake with filter
and the air flow louvered fins, include
a dedicated electric box, which is con-
nected using bayonet joints to the con-
nector, fixed to the unit support struc-
ture.
The form and opening of the flow louve-
red fins were developed in order to have
FUNCTIONING
The same FCL unit can be coupled to
several grid accessories that determine
different functioning modes.
T h e p a r t i c u l a r i n f o r m a t i o n
regarding use is supplied in the
"USER MANUAL".
GLL10R / GLL20R
Check that the Dip Switch settings inside
the electric box correspond to system
requirements, otherwise modify Dip
Switch settings.
The Dip Switch settings affect the unit
functioning mode.
In the unit with 4-speed motors, select
the 3 fan speeds most suitable for the
system from the 4 available.
the best possible distribution of the air,
both when functioning in winter and
summer modes.
Intake takes place through the central
grid, flow through the adjustable peri-
meter slots. In RAL 9010 plastic, it hou-
ses the air filter, which can be easily
extracted for cleaning.
The same basic FCL unit can be con-
figured in several versions by simply
coupling it to different grid units of
the GLL series (mandatory accessory),
which determine the functioning modes:
- GLL 10 R (for Module 600 only)
GLL 20 R (for Module 840 only)
With remote control and manually mo-
veable louvered fins, the IR receiver is
integrated into the grid. GLL-R is com-
plete with electronic thermostat able to
manage all configurations (hot coil with
valve, cold coil with valve, electric re-
sistance in replacement or integration
mode) as well as all functions (heating,
cooling, continuous or thermostat venti-
lation, dehumidification, timed switch-
on/off). In functioning with electric
resistance it is envisioned that the ven-
tilation is only active at maximum and
medium speed.
The electric resistance accessory can
be applied only to units with "Module
600".
FILTERING SECTION
The air filter is inserted in the intake grid.
Mechanical air filter with ABS frame.
Filter with G1 filtering class, self-extin-
guishing class V0 (UL94).
Easy to remove and built with rege-
nerable materials and which can be
washed.