Technical Specifications; List Of Cables Required; Preliminary Checks - Key Automation CT1RD Instrucciones Y Advertencias Para Su Instalación Y Uso

Central para un motor 230 vca, para cierres enrrollables o puerta de corredera
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

TECHNICAL SPECIFICATIONS:

Power supply
Max motor load
Output for accessories power
Flashing light output
Pause time
Work time
Operating temperature
Receiver frequency
Available reception
Max. number of transmitters storage
Impedance of antenna
Capacity

2.4 - List of cables required

The cables required for connection of the various devices in a stan-
dard system are listed in the cables list table.
ELECTRIC CABLE TECHNICAL SPECIFICATIONS:
Connection
Control unit power supply line
Flashing light
Antenna
Transmitter photocells
Receiver photocells
Sensitive edge
Key-switch
* If the power cable is longer than 30 m, a cable with a larger cross-section is required (3x2.5 mm
vicinity of the automation.
** Two cables of 2 x 0.5 mm
2

3 - PRELIMINARY CHECKS

Before installing the product, perform the following checks and in-
spections:
check that the gate or door is suitable for automation;
the weight and size of the gate or door must be within the operating
limits specified for the automation system in which the product is
installed;
check that the gate or door has firm, effective mechanical safety
stops;
make sure that the product fixing zone is not subject to flooding;
high acidity or salinity or nearby heat sources might cause the pro-
duct to malfunction;
in case of extreme weather conditions (e.g. snow, ice, wide tempe-
rature variations or high temperatures), friction may increase, cau-
sing a corresponding rise in the force needed to operate the system;
can be used as an alternative
230 Vac (+10% - 15%) 50-60 Hz
600 W
24 Vac 1,5 W MAX
230 Vac 40 W
da 4 a 120 sec.
da 1 a 180 sec.
-20 + 55 °C
433.92 MHz
fix code/rolling code
1000 TX
50 Ω
50-150 m in unlimited space
The cables used must be suitable for the type of installation; for
example, an H03VV-F type cable is recommended for indoor appli-
cations, while H07RN-F is suitable for outdoor applications.
cable
1 x
cable 3 x 1,5 mm
2
1 x
cable 4 x 0,5 mm
**
2
1 x
cable type RG58
1 x
cable 2 x 0,5 mm
2
1 x
cable 4 x 0,5 mm
2
1 x
cable 2 x 0,5 mm
2
1 x
cable 4 x 0,5 mm
2
the starting torque may therefore exceed that required in normal
conditions;
check that when operated by hand the gate or door moves smoothly
without any areas of greater friction or derailment risk;
check that the gate or door is well balanced and will therefore re-
main stationery when released in any position;
check that the electricity supply line to which the product is to be
connected is suitably earthed and protected by an overload and dif-
ferential safety breaker device;
the system power supply line must include a circuit breaker device
with a contact gap allowing complete disconnection in the condi-
tions specified by class III overvoltage;
ensure that all the material used for installation complies with the
relevant regulatory standards.
maximum allowable limit
20 m *
20 m
20 m (advised < 5 m)
20 m
20 m
20 m
20 m
) and safety earthing is necessary in the
2
EN
15

Publicidad

Tabla de contenido
loading

Tabla de contenido