▶ Transport the tool and batteries individually packaged.
▶ Never transport batteries in bulk form (loose, unprotected).
▶ Check the tool and batteries for damage before use after long periods of transport.
Storage
CAUTION
Inadvertent damage caused by defective battery. A leaking battery may damage the tool.
▶ Always remove the battery before storing the tool.
▶ Store the tool and batteries in a place that is as cool and dry as possible.
▶ Never store batteries in direct sunlight, on heating units or behind a window pane.
▶ Store the tool and batteries in a place where they cannot be accessed by children or unauthorized
persons.
▶ Check the tool and batteries for damage before use after long periods of storage.
8 Troubleshooting
If the trouble you are experiencing is not listed in this table or you are unable to remedy the problem by
yourself, please contact Hilti Service.
8.1 The crimping tool is not in working order.
Malfunction
The LEDs on the battery indi-
cate nothing.
1 LED on the battery blinks.
4 LEDs on the battery blink.
Red LED => lights continu-
ously and a warning tone is
emitted.
Red LED => blinks at short
intervals and a warning tone
is emitted.
Red LED => lights briefly and
no warning tone is emitted.
8.2 The crimping tool is in working order.
Trouble or fault
The battery runs down more
quickly than usual.
The battery does not engage
with an audible double click.
Red LED => blinks at long
intervals and a warning tone
is emitted.
Printed: 27.07.2017 | Doc-Nr: PUB / 5365804 / 000 / 00
Possible cause
The battery is not correctly in-
serted.
The battery is discharged.
The battery is too hot or too cold.
The battery is discharged.
The battery is too hot or too cold.
The crimping tool has been briefly
overloaded.
Technical problem.
The state of charge of the battery
is too low to allow a complete op-
erating cycle.
The tool has overheated.
Possible cause
Very low ambient temperature.
The retaining lugs on the battery
are dirty.
Crimping pressure not achieved
(tool was used incorrectly).
Action to be taken
▶ Push the battery in until it
engages with a double click.
▶ Change the battery and charge
the empty battery.
▶ Allow the battery to cool
down or to warm up to room
temperature.
▶ Change the battery and charge
the empty battery.
▶ Allow the battery to cool
down or to warm up to room
temperature.
▶ Allow the tool to cool down.
▶ Incorrect operation is possible!
Contact Hilti Service.
▶ Change the battery and charge
the empty battery.
▶ Allow the tool to cool down.
Action to be taken
▶ Allow the battery to warm up
slowly to room temperature.
▶ Clean the retaining lugs and refit
the battery.
▶ Make sure that the tool is used
correctly and check the crimped
/ pressed part if unsure.