BFT MICHELANGELO Serie Instrucciones De Uso página 28

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41
TABLE "B" LOGIC MENU -
Logic
default De nition
Automatic
ON
closing time
OFF
2-step logic
ON
3-step logic
Opening Impulse
ON
lock
Impulse lock TCA
OFF
OFF
Pre alarm
Hold-to-run
OFF
control device
OFF
Rapid closing
P h o t o c e l l s o n
ON
opening
OFF
Photocell test
Direction
OFF
Reversal
OFF
TIMER OPEN
ON
SCA Alarm
Fixed code
OFF
Radio transmitter
ON
programming
Master/Slave
OFF
28
- MICHELANGELO
INSTALLATION MANUAL
ON:
Activates automatic closing
OFF: Excludes automatic closing
Note: automatic closing on TIMER release cannot be deactivated.
ON:
Enables the 2-step logic (prevails over the "3-step logic").
OFF: Disables the 2-step logic, activating the 4-step logic if the "3-step logic" is OFF.
ON:
Enables the 3-step logic (if the "2-step logic" is OFF).
OFF: Disables the 3-step logic, activating the 4-step logic if the "2-step logic" is OFF.
Barrier
closed
on closing
open
on opening
after stop
ON:
The Start impulse has no e ect during the opening phase.
OFF: The Start impulse becomes e ective during the opening phase.
ON:
The Start impulse has no e ect during the TCA dwell period.
OFF: The Start impulse becomes e ective during the TCA dwell period.
ON:
The blinker comes on about 3 seconds before the motor starts.
OFF: The blinker comes on at the same time as the motor starts.
ON:
Hold-to-run operation: the manoeuvre continues as long as the OPEN and CLOSE control keys
are kept pressed. The radio transmitter cannot be used.
OFF: Normal impulse operation.
ON:
Closes barrier after photocell disengagement, before waiting for the end of the TCA (automatic
closing time) set.
OFF: Command not entered.
ON:
In case of obscuring, this excludes photocell operation on opening. During the closing phase, it
immediately reverses the motion.
OFF: In case of obscuring, the photocells are active both on opening and on closing. When a photocell
is obscured on closing, it reverses the motion only after the photocell is disengaged.
ON:
Activates photocell check
OFF: Deactivates photocell check
ON: For right-hand tted barrier (see Par. Right-hand tting)
OFF: For left-hand tted barrier
IMPORTANT: Default has no e ect on the logic.
Special dip switch 1 on second-generation universal programmers.
ON:
OPEN pressed for over 3s becomes TIMER
OFF: TIMER input disabled
Signaling output on second-generation universal programmers.
ON:
The SCA contact (terminals 21-22) behaves as follows:
with barrier open and on opening: contact closed (warning light on)
with barrier closed:contact open: (warning light o )
on closing: intermittent contact (blinking)
OFF: The SCA contact closes according to the modes set by the Alarm Time parameter.
ON:
The receiver is con gured for operation in xed-code mode.
OFF: The receiver is con gured for operation in rolling-code mode.
ON:
This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2, T3 or T4) of a transmitter
already memorised in standard mode by means of the radio menu.
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2, T3 or T4) of a transmitter to
be memorised.
The receiver exits the programming mode after 10s, other new transmitters can be entered before
the end of this time.
This mode does not require access to the control panel.
OFF: This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate Radio menu.
ON:
The control panel is set as Master in a centralised connection.
OFF: The control panel is set as Slave in a centralised connection.
Description
Response to the START impulse
2 steps
3 steps
opens
opens
closes
closes
stop + TCA
opens
opens
4 steps
opens
stop
closes
stop + TCA
opens

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Michelangelo 60Michelangelo 80

Tabla de contenido