9.8.1.3.

SMOKE EXTRACTOR CALIBRATION

You can increase or decrease the fixed value with the keys
factory is 0 and the range is between -7 to +7. Consider that each value you modify is
equivalent to modify proportionally 5% each power the value of fan speed (rpm) assigned to
the smoke extractor. The selected value should be confirmed with the key
out of the menu.
Consider that as more smoke extractor speed the more smoke extraction we have but
also the more air inlet in the combustion chamber (larger flame). In case you see the stove
does not burn properly or the mix combustible/air is not the right one try with this loading
parameter.
9.8.2.

MENU 2. HEATING MANAGE

This menu manages the combustion parameters. It has different submenus:
9.8.2.1.

BOILER THERMOSTAT

This menu allows to select the water temperature in the boiler. You can select between 40º
and 80º C, that is to say the temperature you want your boiler to reach.
The selected value should be confirmed with the key
When the water temperature of the boiler reaches the requested value by the user, the boiler
starts mode "stand by", i.e. starts modulation lowing the power to adequate to the selected
temperature of the water and keep on working. In this case it is possible that your house
do not reach the temperature requested from the external thermostat because the water
temperature value that you have fixed is low for your comfort temperature. We recommend
putting an enough temperature value (70-75º) to allow the boiler keep on working and reach
your house comfort temperature
9.8.2.2.

PUFFER TANK TEMPERATURE

This menu allows selecting the temperature in the puffer tank. In case you do not want to use
your boiler to produce sanitary water you should skip this menu. You can select between 40º
and 55º C, that is to say the temperature you want your boiler to reach. The selected value
should be confirmed with the key
9.8.2.3.

SUMMER / WINTER MODE

This menu has two options: "Summer" and "Winter". In case we chose the winter mode the
boiler will be able to manage heating and sanitary water. Sanitary water will have priority and
should be installed directly to the boiler. In case we have only one heating circuit the boiler
will work same way but only with this circuit parameters. The use of this working mode is
recommended during the coolest periods.
In case we chose the summer mode it will work when we install a system of sanitary water
because the boiler consider that in summer we do not need heating the house, only sanitary
water. If our installation do not have sanitary water we recommend select the winter mode.
Remote Control
OFF
ON
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
or
before going out of the menu.
before going out of the menu.
9.8.3.
CONTROL
IMPORTANT NOTE. Your boiler does not have any remote control, reason why, to
ensure the proper funtion of the boiler, it is important this menu is disabled (OFF)
. The fixed value from
before going
MENU 3. REMOTE
57
Settings
Fan Calibration
0
Min: -7 Max: 7
Settings
Boiler Thermostat
75
Min: 40 Max: 80
Settings
Buffer Thermostat
45
Min: 40 Max: 55
Summer - Winter
Winter
Summer
HYDROBOX, HYDROTEX AND HYDROCONFORT