On all models Hydrobox and Hydrotex, you must also clean the existing register in the bottom right of the
boiler, you have to remove the side chamber and then perform the following operations:
-
Remove the record covers by loosening the different screws.
-
Clean the ash deposited in the records.
-
Mount back the covers.
-
Check the tightness of the records.
In the Hydroconfort model with ash compactor, it is necessary to clean this area. In order to do
this, you can find two registers that are accessible by the right side of the boiler, disassembling
the chamber of that side. As in previous occasions, you must:
-
Remove the record covers by loosening the different screws.
-
Clean the ash deposited in the records.
-
Mount back the covers.
-
Check the tightness of the records.
11.8.
SEASONAL STOPPAGES
If the boiler is not going to be used for a long time it is advisable to leave the fuel tank empty,
as well as the auger in order to avoid the fuel compacting or gaining moisture and expanding.
It is necessary to clean the boiler and the smoke duct by removing the ash and other residues,
close all doors of the equipment. It is recommended to clean the chimney at least once a year.
Meanwhile, check the seals because if they are not in good condition (they do not seal the door), they do not ensure the proper operation
of the boiler. For this reason, it would be necessary to change them. You can find this spare part in the same Bronpi distributor where you
bought your boiler. If there is humidity in the place where the boiler is installed, put absorbent salts inside the equipment. Protect the internal
parts with neutral vaseline in order to keep the appearance overtime time.
Your boiler has a system to prevent the blocking of the pump due to calcareous sediments of the water of the installation. For this
reason, it is necessary that, during the seasonal shutdowns, the boiler is connected to the electric mains since it will automatically
work for several seconds to move the impeller and prevent its locking.
11.9.
MAINTENANCE REVIEW
It is also advisable to check and clean at least once a year, all the ash registers in the boiler.
Your boiler has a preventive maintenance notice established at 1200 hours of operation, which will remind you MANDATORY of the need to
clean the reservoirs of your boiler as soon as possible. These operations should be done exclusively by an authorised technician.
This message is not an alarm, but a reminder or warning. Therefore you will be able to use your boiler meanwhile this message is displayed
but you have to prevent the immediate cleaning of your boiler.
Please, bear in mind that depending on fuel and usage patterns the boiler could need to be cleaned before the1200 hours are completed or
possibly after this. This depends on the quality of the fuel used, the smoke installation, and the proper regulation of the boiler.
In the following table (also pasted on your boiler in the fuel tank cover) you can check the frequency of the maintenance tasks and who must
do them.