9.9.2.3.
NODE LIST
This menu shows the communication direction of the board, type of board and firmware
versions.
9.9.3.

MENU 7. SYSTEM MENU

This menu allows the access to technical menu. This access is protected by password and
is only available for our after sales service. Otherwise, non authorized person acceding this
menu will follow by a warranty lost.

10. ALARMS

In case of an anomaly during operation, the electronics of the boiler intervene and highlight
the irregularities that have taken place in the standard operation of the boiler, depending on
the type of fault.
Every alarm situation puts the boiler to be an automatic "lock out" state. By pressing
appropriate cooling temperature, the user can restart it up (Check the chapter 9.7.11.). The list of alarm codes that we can see and the
description, are shown in the following table:
Alarm Code
Description
Er01
Intervention of the safety thermostat, even when the boiler is turned off
Er02
Intervention of the safety air pressure switch, only when the smoke fan is working
Er03
Switching off of the boiler due to smoke temperature decrease Possible lack of fuel or blockage of it.
Er04
Turning off the boiler due to overheating of the water temperature
Er05
Switching off of the boiler due to overheating of the smoke temperature
Er07
Error Encoder: the encoder of the smoke extractor does not receive signal
Er08
Error Encoder: the adjustment of the smoke extractor speed is not possible
Er09
Low water pressure
Er10
High water pressure
Er11
Values DATE/TIME are not exact after a long power failure
Er12
Ignition of the boiler unsuccessful
Er15
Power dip
Er16
Error Display communication
Er17
Smoke extractor do not regulate due to an excess or fault of flow
Er18
Lack of fuel (pellet)
Er23
SHW accumulator probe not connected
Er25
Error of the burner cleaning base. Only mod. HydroConfort.
Er27
Error broken cleaning motor.
Er34
Minimum flow of the flow sensor
Er35
Excessive flow of the flow sensor
Er39
Flow sensor broken
Er41
The primary air flow is insufficient during the check of the boiler
Er42
The primary air flow is high
Er47
Auger Encoder Error: the encoder of the auger does not receive signal
Er48
Auger Encoder Error: the speed regulation of the auger is not possible
Er52
Er52 IO module error I2C
Maintenance Error: it signals that operating hours set have been reached (1200 hours). You need to call the
Mant
technical assistance.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
247 MSTR FSYSI01000036.
016 KEYB FSYSF02000022.
we can unlock it. Once the boiler has reached the
61
Node List
System Menu - Password
0000
HYDROBOX, HYDROTEX AND HYDROCONFORT
1.1 0
0.0 0