Zibro S30 Serie Manual De Instalación página 71

Ocultar thumbs Ver también para S30 Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22
Fig. 6
Do not block water flow by a rise.
1.
When connecting extension drain hose, insulate the connecting part of extension drain hose with a
shield pipe, do not let the drain hose slack.
Fig. 7
Connective pipe
2.
For the left-hand and right-hand piping, remove the pipe cover from the side panel. The pipe cover
must be kept as it may be used when relocate the air conditioner to any other place.
Pipe holder
Pipe Cover (right)
Right piping
Fig. 8
ATTENTION
Always use the highest care when bending the piping. Make sure that the piping always is
bended and not nodded. In case of a nodded pipe: do not attempt to install this nodded pipe as
this is a potential refrigerant leak.
4. Indoor unit installation
For SC 30xx models
1.
Pass the piping through the hole in the wall.
2.
Put the upper claw at the back of the indoor unit on the upper hook of the installation plate, move the
indoor unit from side to side to see that it is securely hooked.
3.
The female half can be easily past through by lifting the indoor unit with a cushioning material bet-
ween the indoor unit and the wall. Get it out after finishing it.
4.
Push the lower part of the indoor unit up on the wall. Then move the indoor unit from side to side, up
and down to check if it is hooked securely.
.
Do not put the end of drain hose
into water.
Upper Hook
Lower Hook
Cushion
material
Pipe Cover (left)
Left piping
Left back piping
Right back piping
.
.
4
71

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sc30 serie

Tabla de contenido