4. OPERATING ANG PROGRAMMING

4.1 CONTROL PANEL

The valve incorporates in the electronic module cover a panel with push buttons and
LEDs to indicate the function being performed by the valve.
If there is a power cut, the backwash and rinse times will remain stored in the valve until
the valve once has a power supply again.
4.2 TIMED BACKWASH SWITCH
The bottom right hand area of the electronics board (2) (APPENDIX 2 Item 2) contains
a microswitch used to connect ("ON" position) and disconnect ("OFF" position) the 7-day
cleaning function.
The 7-days timer resets when:
- The 7-days cleaning function has completed.
- A pressure switch backwash has completed.
- The backwash is fi nished though a push button.
- Power is connected or reconnected after a power outage.
All cleaning will be pressure cleaning while the 7-day microswitch is set to the "OFF"
position.

4.3 PROGRAMMING.

Filtration:
1º Programme the fi ltration time via the timer to be found in the control box.
2º Programme backwash time using the push button control on the cover of the
electronic module, pressing (+) or (-) to select the desired time shown in minutes on
the LED display (when the valve performs this function the LED display will fl ash).
3º Programme rinse time using the push button control on the cover of the electronic
module, pressing (+) or (-) to select the desired time shown in minutes on the
LED display (when the valve performs this function the LED display will fl ash).
If any button is pushed during the wash and rinse cycles, in order to change the
time programmed, the time entered will remain programmed for the next time the
appliance is used.
Power supply: LED that indicates that the valve's power
supply connection has been correctly done.
MODBUS Communication: In case of connection in done
through MODBUS, it indicates when data is sent or received.
Drainage: Push button with LED that activates the drainage
function and indicates that this function is in process.
Backwash: Push button with LED that activates the
backwash and rinse function. The LED fl ashes when the valve
is moving to the position and it also indicates the activation
of the pressure switch.
Backwash time: the push buttons can increase or reduce
the backwash time and the activation of one of the LEDs
shows the minutes of programmed wash. It fl ashes when
the function is running.
Rinse time: the push buttons can increase or reduce the
rinse time and the activation of one of the LEDs shows the
rinse time selected. It fl ashes when the function is running.