Making reference to Fig. 18, proceed as follows:
1) Remove protection cover "C" positioned on the barrier.
2) Remove cover "D" from the SLM" bracket.
3) Having laid the connection cables to the blinker, fix the SLM2 bracket to
the barrier by means of the appropriate screws (supplied).
4) Spacer "E" is only necessary for the "PA" series blinkers (suitable for the
receiver antenna). For blinkers without antennas, the base is to be directly
fixed to the SLM2 bracket.
5) Reposition cover "D".
6) Complete fitting and wiring as specified in the instructions for LAMPO/
LAMPO-PA.
6.5) Photocell fitting (Fig. 19)
The photocell can be installed on the MOOVI barrier as follows:
1- By directly fixing the CELLULA 130 photocell to the side of the barrier
(Fig. 19 "A")
2- By fastening the MOOVI 130 photocell post to one of the front fittings
(Fig. 19 "B")
A) Cellula 130 fitting
1) Remove the protection cover positioned on the barrier.
2) Lay the wiring needed for photocell connection.
3) Fit the photocell as shown in Fig. 19 A by means of the appropriate
screws.
Refer to the instruction sheet for Cellula 130 for further information.
B) MOOVI 130 post fitting
1) Remove the protection cover positioned on the barrier.
2) Lay the wiring needed for photocell connection.
3) Fit post "F" and protection frame "G" as shown in Fig. 19B.
The post is fastened from inside the barrier by means of 3 screws (sup-
plied).
4) Fit the photocell to the post, as shown in the instruction sheet for Cellula
130.
Refer to the instruction sheet for Cellula 130 for further information.
6.6) Moovi accessories: boom length limits and balancing (Fig.20)
All barriers belonging to the MOOVI series are equipped with a hooking
bracket with 3 securing points located on the device for boom balancing
(Fig. 20 - ref. A points A-B-C).
The ideal securing point for correct balancing of the boom must be chosen
according to the barrier type and to the length of the boom and accessories
installed.
Tab.1 of Fig.20 shows the weight expressed in kgs by linear meter (kg/m)
for each accessory.
When the supporting leg Moovi GA/GAMA is used, it is necessary to calculate
the arbitrary weight in Kg/m, using the following formula:
where L stands for the length of the boom.
Then proceed as follows:
1) Sum up the total linear weight of the accessories installed (including
boom weight).
2) Find the crossing point between the length of the boom and the total
weight of the accessories on the diagram, making reference to the MOOVI
model.
3) The point found in this way will indicate the correct hooking point (A-B-
C).
Example
MOOVI 50 with:
(boom measuring 4,0m + BIR + GAMA +1PCA).
(1,028+0,510+(1,2/4,0)+0,160)= 1,97
The crossing point between value 1,97 and boom length equal to 4,0 is within
the "A" area of MOOVI 50 graph. "A" hooking point will therefore be suitable
for correct boom balancing.
Calibrate the spring as described in paragraph 7.
WARNING!:
The securing points marked with A and B can be used with MOOVI 50
only.
The securing point marked with C can be used with MOOVI 30MM only.
If the point found is within the crossed area that means that installation is
not possible and it is necessary to shorten the boom or reduce the number
of accessories.
If no accessory is used, only use the weight of the "PA" boom to find the
securing point.
7) BAR BALANCING (Fig.9)
-
Activate the emergency release (fig.14).
-
Position the bar at about 45° (fig.9). The bar must remain still.
-
If the bar tends to open, unload the spring by operating on the "T" tie
rod.
-
If the bar tends to close, load the spring by operating on the "T" tie rod.
12
- MOOVI 30-50 UL CSA Ver. 01
INSTALLATION MANUAL
Kg/m = 1,2/L
-
In both cases, load or unload the spring until the bar remains still at about 45°.
-
Reset the motorised operation by rotating the release key to the opposi-te
direction (fig.14).
WARNING! During the closing operation, the balancing spring must never
be reduced to a pack (be totally compressed). Fig.9 indicates the position
where the minimum value of the compressed spring is measured with the
rod in the opening (vertical bar) position.

8) ELECTRICAL INSTALLATION SET-UP

WARNING: before opening the door, make sure that the spring has
been unloaded (rod at 43°). Set up the electrical installation (fig. 10) with
reference to the current regu-lations for electrical installations.Keep the mains
power supply con-nections definitely separate from the service connections
(photocells, elec-tric edges, control devices etc.).
Warning! For connection to the mains, use a multipolar cable having
minimum 3x1.5mm
cross section and complying with the previously
2
mentioned regulations (for example, if the cable is not protected, it must
be at least equal to H07 RN-F, whereas if it is protected it must be at
least equal to H07 VV-F with a 3x1.5 sq mm
Connect the control and safety devices in conformity with the previously
mentioned installation standards. Fig.10 shows the number of connections
and section for a 100m length of power supply cables; for greater lengths,
calculate the section for the true automation load. When the auxiliary con-
nections exceed 50-metre lengths or go through critical disturbance areas,
it is recommended to decouple the control and safety devices by means of
suitable relays.
The main automation components are (fig.10):
I)
Type-approved adequately rated omnipolar circuit-breaker with at least
3,5 mm contact opening, provided with protection against overloads
and short circuits, suitable for cutting out automation from the mains.
Place, if not al ready installed, a type-approved differential switch
with a 0.03A threshold just before the automation system.
QR)
Control panel and incorporated receiver.
S)
Key selector.
AL)
Blinker with tuned antenna.
M)
Actuators.
A)
Bar.
F)
Rest fork.
CS)
Electric edge.
CC)
Edge control.
Ft,Fr) Pair of photocells.
CF)
Photocell post.
T)
1-2-4 channel transmitter.
9) TERMINAL BOARD CONNECTIONS
WARNING: before opening the door, make sure that the spring has been
unloaded (rod at 43°). First pass the appropriate electric cables through the
raceways and fix the various automation components to the chosen points,
then connect them following the directions (Fig.15) and diagrams contained in
the control unit instruction manual.Carry out phase, neutral and (compulsory)
earth connections. The protection wire (earth) with yellow/green insulating
sheath must be connected to the appropriate terminals marked by their symbol.
It is absolutely necessary to avoid operating the automation system without
adequate protection. This can jeopardise personal and product safety. In no
circumstances must the automation system be activated before carrying out
all connections and checking the efficiency of all safety devices.
Keep the low voltage connections definitely separated from the power supply
connections.

10) LIMIT SWITCH SETTING

WARNING: before opening the door, make sure that the spring has been
unloaded (rod at 43°). The barrier is provided with electrical limit switches
and end-of-stroke mechanical stop devices.There must be a rotation margin
(about 1°) on closing and opening between the electrical limit switches and
mechanical stop devices (fig.11).
The adjustment is carried out as follows:
-
Activate the manual release, bring the bar to its completely open position
(perfectly vertical).
-
Manually advance the bar by about 2° with respect to the vertical
position.
-
Set the opening microswitch (fig.12 ref. SWO) by loosening the dowel (fig.
13 ref. G) and moving the cam (fig.13 ref. C) until the microswitch trip is
heard (or checking that the respective control unit LED switches off).
-
Manually bring the bar to its completely closed position resting onto the
fork (fig.11 ref. F). Check that the bar is perfectly horizontal using a level
(fig.11 ref. L).
cross section).
2