Lenze L-force 9400 Instrucciones Para El Montaje página 21

Ocultar thumbs Ver también para L-force 9400:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Displays
Pos.
Colour
MS
Green
EN
Yellow
ME
Red
PS
Red
DE
Red
EDK94AYAD DE/EN/FR/ES/IT 2.0
State
Description
On
Drive-based safety is initialised faultlessly.
Drive-based safety is initialised faultlessly. Internal
Blinking
communication to the standard device is not possible.
Off
Drive-based safety is not initialised.
Acknowledgement is not possible.
On
Controller enabled
Off
Non-safe display "STO"
System error:
After a serious internal error, STO is activated.
On
Can only be reset by switching the 24V supply.
Error:
After an internal error or an error at the safe
inputs, a standstill function is activated.
Blinking
The safety class is quit.
Acknowledgement is possible.
Fault:
A monitoring function has responded and
activated a standstill function.
Flashing
The safety class is not quit.
Acknowledgement is possible.
Off
Error-free operation
Error PROFIsafe:
Communication is not possible.
On
Acknowledgement is possible.
Blinking
No valid PROFIsafe configuration
Off
PROFIsafe is error-free.
The module is not accepted by the standard device
(see notes given in the documentation for the
On
standard device).
21

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

E94ayad - sm300

Tabla de contenido