6. START-UP

6.1. Leds check

The following table shows that status of the LEDs in relation to
the status of the inputs (the closed at rest automated system
condition is shown in bold).
Check the status of the signalling LEDs as per table below:
Tab. 1 - Operation of inputs status LEDs
LED
ON (closed contact)
STOP
Command disabled
OPEN A Command enabled
OPEN B Command enabled
BUS
See par. 7.2

6.2. Programming the Dips-switch

The settings of the DS1 dip-switch for programming the force
and the type of motor are shown in the following table.
Tab. 2 - DS1 programming (default settings in bold)
Dip-switch
LOW FORCE
MEDIUM - LOW FORCE
MEDIUM - HIGH FORCE
HIGH FORCE
COMPAS
MISTRAL 324 ENV
G-BAT 324 ENV / G-BAT 424 ENV
MISTRAL 324 / MISTRAL 324 LS
MISTRAL 424 / MISTRAL 424 LS
SIROCCO 2524 / SIROCCO 2524 LS
ELITE 324 / ELITE 424
G-BAT 324 / G-BAT 424
TRIGON 02-24
ROLLER 24
NOT USED
Before performing the Setup, select the operator con-
nected to the BRAIN 15 equipment with the DS3 and
DS4 dip-switches.
OFF (open contact)
Command enabled
Command disabled
Command disabled
Description
Guide for the installer

6.3. Time - setup learning

Before any manoeuvre is executed, a SETUP cycle must
first be run.
If the motor type is changed with the DS3 and DS4 dip-
switches after the SETUP , a new SETUP is requested.
When the board is powered up and a SETUP cycle has never
been executed, LEDs LD4 and LD5 begin to flash slowly to
signal that a SETUP cycle must be executed.
There are two possible types of SETUP: AUTOMATIC and
MANUAL

6.3.1. AUTOMATIC SETUP

1.
Set the operators for manual operation and take them
to approx. half of the required opening.
2.
Lock the operators again and make sure that they
cannot be moved by hand.
3.
Press and hold down the SETUP key until the LEDs LD 4
and LD 5 light on a steady beam.
4.
Release the Setup key. The leaves start, one at a time,
the opening movement until they reach the mecha-
nical stop point.
If one or both leaves start moving with a closing
manoeuvre, cut power to the system and reverse
the power cables of the connected motor/motors.
Supply power to the system and resume from point
1.
5.
After having reached the opening stop point, the leaves
start, one at a time again, the closing phase until the
gate is completely closed.
6.
After a short pause the leaves start, one at a time,
an opening phase until they reach the mechanical
stop point.
7.
When the opening position has been reached, the
setup phase is completed. If it has been performed
correctly, the LEDs LD4 and LD5 turn off. If this is not
the case, the LEDs LD4 and LD5 flash and the setup
procedure must be repeated.
With the AUTOMATIC SETUP procedure, the leaf delay
at closure and the pause time are set by default. To
change these values, a second level programming
must be executed (see paragraph 6.3.4.).

6.3.2. MANUAL SETUP

1.
Set the operators for manual operation and take them
to approx. half of the required opening.
2.
Lock the operators again and make sure that they
cannot be moved by hand.
3.
Press and hold down the SETUP key until the leaves start,
one at a time, an opening movement until they reach
the mechanical stop point.
If one or both leaves start moving with a closing
manoeuvre, cut power to the system and reverse
the power cables of the connected motor/motors.
Supply power to the system and resume from point
1.
4.
After having reached the opening stop point, the leaves
start, one at a time again, the closing phase until the
gate is completely closed.
5.
After a short pause, leaf 1 starts an opening phase.
Send an OPEN command to determine the start of the
6.
decelerated part and wait until the opening mecha-
nical stop point is reached.
7.
Leaf 2 starts the opening phase.
8.
Send an OPEN command to determine the start of the
decelerated part and wait until the opening mecha-
nical stop point is reached.
9.
When at rest, leaf 2 starts the pause time count. At the
end of the required time, send an OPEN command.
BRAIN 15