Maintenance And Cleaning - Binzel ABIMIG WT Instructivo De Servicio

Mig/mag antorcha de soldadura
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

®
ABIMIG
WT

8 Maintenance and cleaning

Scheduled maintenance and cleaning are prerequisites for a long service life
and trouble-free operation.
DANGER
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout all maintenance,
servicing, assembly, disassembly and repair work:
• Switch off the power source.
• Close off the gas supply.
• Close off the coolant supply.
• Disconnect the coolant supply and return hoses.
• Close off the compressed air supply.
• Disconnect all electrical connections.
DANGER
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and
damage.
• Replace any damaged, deformed or worn parts.
DANGER
Risk of burns
Risk of burns from hot coolant and hot surfaces.
• Switch off the coolant recirculator before starting maintenance, servicing,
assembly, disassembly or repair work.
• Allow the welding torches to cool down.
• Wear the correct protective gloves.
WARNING
Risk of burns
The welding torches reach very high temperatures during welding.
• Allow the welding torches to cool down.
• Wear the correct protective gloves.
8 Maintenance and cleaning
EN - 13

Publicidad

Tabla de contenido
loading

Tabla de contenido