Macurco CD-xx H/MC Manual
Figure 4-1 Board View
4.5.1 Selecting Default Configuration – "dEF"
To select the Default Configuration, in normal mode, push the Next button to get to "Con" or the Configuration menu. Then
push the Enter button to enter the Con menu. The first selection is the "dEF" or Default setting. Push Enter. If it is already in
Default configuration, there will be no action. If it is not already in Default configuration, "nO" will be displayed. Push Next to
change it to "YES" (flashing) then push Enter to confirm the change (solid) and push Enter again to return to "dEF" in the con
menu. Push Next until "End" is displayed then push Enter to get back to normal operation.
4.5.2 Power-Up Test Setting – "PUt"
To select the Power Up Test Configuration, in normal mode, push the Next button to get to "Con" or the Configuration menu.
Then push the Enter button to enter the Con menu. Then push the Next button to get to the second selection "PUt" or Power
Up Test setting. Push Enter. If the test is "On" push Next to turn it "OFF" (flashing) then push Enter to confirm the change (solid)
and push Enter again to return to "PUt" in the Con menu. Push Next until "End" is displayed then push Enter to get back to
normal operation.
4.5.3 Display Setting – "dSP"
To select the Display Configuration, in normal mode, push the Next button to get to "Con" or the Configuration menu. Then
push the Enter button to enter the Con menu. Then push the Next button to get to the third selection "dSP" or Display setting.
Push Enter. If the display is "On" push Next to turn it "OFF" (flashing) then push Enter to confirm the change (solid) and push
Enter again to return to "dSP" in the Con menu. Push Next until "End" is displayed then push Enter to get back to normal
operation.
4.5.4 Buzzer Setting – "bUZ"
To select the Buzzer Configuration, in normal mode, push the Next button to get to "Con" or the Configuration menu. Then push
the Enter button to enter the Con menu. The fourth selection is the "bUZ" or Buzzer setting. Push Next twice to get to "bUZ"
then Enter. If the display is "On" push Next to turn it "OFF" (flashing) then push Enter to confirm the change (solid) and push
Enter again to return to "bUZ" in the Con menu. Push Next until "End" is displayed then push Enter to get back to normal
operation.
21 |
REV.A
[34-2900-0510-8]
P a g e