OPERATION AND LOGIC
IGNITION
Once the previously listed points have been checked, press key
15 minutes are available for the ignition phase. After ignition and after reaching the control temperature, the
stove interrupts the ignition phase and switches to PREPARATION.
PREPARATION
During the preparation phase, the stove stabilises combustion, increasing it progressively, to then start ventilation and switch to WORK.
WORK
During the work phase, the stove will function at the set power and work to reach the set room temperature. See next heading.
REGULATION OF SET THERMOSTAT
When the key
is pressed, the set temperature is viewed; it can be changed using keys
The change must be confirmed by pressing the key
LOW TA HOT
If the temperature is set at "LOW TA" (set below the limit of 7°C), the stove will always run at minimum.
If the setting is on "HOT" (set above the limit of 40°C) the stove will not modulate, running only and always at the set power.
REGULATION OF SET POWER
The set power has 5 operating levels, When key
Power 1 = minimum level - Power 5 = maximum level.
The change must be confirmed by pressing the key .
WORKING WITH ROOM SENSOR STANDARD
The appliance monitors the room temperature using a sensor incorporated into the handheld.
Once the set temperature has been reached, it will automatically switch to the minimum power level or turn o , activating the STAND BY,
function, reducing pellet consumption to a minimum.
By factory default, the STAND BY function is always set to OFF.
For information on its activation and logic, follow the instructions on the next page, chapter: STAND BY.
BURN POT CLEANING
During the working phase, the stove has an internal timer, which after a pre-set period of time cleans the burn pot.
This phase is shown on the display, it interrupts the pellet loading and increases the speed of the ue gas exhaust motor for a programmed
period of time. When the cleaning phase is nished, the stove will re-start automatically and continue the working phase, returning to the
selected power level.
SWITCH OFF
Press the key
for three seconds.
Once this operation has been performed, the appliance automatically enters the switch-o phase, blocking the supply of pellets.
OK
The ue gas exhaust motor and the hot air ow motor will remain on until the stove temperature has dropped below the default
parameters.
RE IGNITION
The stove can be re-ignited only if the ue gas temperature has lowered, and if the pre-set timer has been reset.
72
for three seconds to ignite the stove.
OK
OK
.
is pressed, the set power is displayed; it can be changed using keys
OK
.
OK
ENGLISH
or
from LOW TA 07°C to 40°C - HOT.
OK
or
.
OK