SET CHRONO
This function allows the generator's ignition and switch-o to be automatically programmed. By factory default, the SET CHRONO is disabled.
The chrono allows the programming of 4 time slots within a day, which can be used every day of the week. Ignition and switch-o times can
be set for each time slot, along with the speci c days of application for the programmed time slot and the desired temperature. Current day
and time settings are essential for the correct operation of the Chrono.
ENABLE CHRONO
Allows the chrono and the di erent stove time slots to be enabled/disabled.
Chrono activation
Programming 1
Programming 2
PRG 1 4
Allows to set the on/o time, the days of use of the scheduled time slot and the desired temperature (low - 7° - 40° - hot). Current day and time
settings are essential for the correct operation of the Chrono.
To set: OK > SET CHRONO > SET PRG1 4.
Ignition time
Switch-o time
RECOMMENDATIONS
The ignition and switch-o times must be within the space of one
day, from 0 to 24 and not over several days.
Before using the chrono function, set the current day and time.
Then check that the points listed in the "DATE/TIME" sub-chapter
have been followed, so that the chrono function works. Aside from
programming it, activate it as well.
WHEN THE WEEKLY PROGRAMMER IS ACTIVE, THE RELATIVE ICON WILL BE SHOWN ON THE HANDHELD
DISPLAY.
74
EXAMPLE
Switch-o time 18:00
Switch-o time 05:00
ENGLISH
Activated
Not activated
Programming 3
Programming 4
Programming 1
Set temperature
Enabled days
Disabled days
1= Monday
7= Sunday
Ignition time 07:00
CORRECT
Ignition time 22:00
INCORRECT