SETTINGS

DATE/TIME
Š
LANGUAGE
Š
SET DEGREES
Š

DISPLAY

The "DISPLAY" menu allows:
Š Regulation of Display contrast
Š Activation/Deactivation of backlight.
Š Enabling/disabling of acoustic signal.
To set: OK > SETTINGS > DISPLAY.

STAND BY

The STAND-BY function is used if the stove needs to be turned o immediately or the modulation
via an additional thermostat is required. The display will feature the word STAND-BY which indicates
the active function.
To set: OK > SETTINGS > STANDBY.
STAND BY FUNCTION SET TO ON
When the STAND BY. function is active (ON), if the room temperature exceeds the set value plus DELTA T OFF, the stove will switch o after
a pre-set (default) delay period, and STAND BY will be displayed on the screen.
When the room temperature is lower than the set value less DELTA T ON and the stove has cooled, it will start to work again at the set power,
and work will be displayed on the screen.
STAND BY FUNCTION SET TO OFF FACTORY SETTING
When the STAND-BY function is not activated (OFF), if the stove reaches the set room temperature, it will switch to the minimum power level,
modulating and displaying modulation on the screen. When the room temperature is lower than the set value, the stove will start to work
again at the set power, and work will be displayed on the screen.
STAND BY WITH ADDITIONAL THERMOSTAT OPTIONAL
STAND BY FUNCTION SET TO OFF FACTORY SETTING
When the STAND-BY function is not activated (OFF), if the stove reaches the room temperature set on the supplementary thermostat (open
contact), it will switch to the minimum power level and display
set value on the supplementary thermostat (closed contact), the stove will start to work again at the set power, and
on the screen.
STAND BY FUNCTION SET TO ON
If the STAND-BY function is activated (ON), when the room temperature set on the supplementary thermostat is reached (open contact), the
stove will switch o after a pre-set (default) delay period, and STAND - BY will be displayed on the screen.
When the room temperature is lower than the value set on the supplementary thermostat (closed contact), the stove will start to work again
at the set power, and
will be displayed on the screen
WORK
FOR CORRECT OPERATION, SET THE ROOM TEMPERATURE TO LOW-TA
THIS FUNCTION IS NOT RECOMMENDED FOR ENVIRONMENTS WITH SCARCE THERMAL INSULATION OR WHERE
THERE MAY BE SHARP FLUCTUATIONS IN TEMPERATURE: DOORS OR WINDOWS CONSTANTLY OPENED.
SEE CHAPTER: COMMISSIONING SETTINGS.
Š Set the timer to turn o
backlight.
Š Set the timer to turn o the Display (sleep
mode).
on the screen. When the room temperature is lower than the
MODULATION
ENGLISH
the Display
WORK
will be displayed
75