First Load; Delta T; Reset; Additional Functions - monolith EXTRA Manual Del Usuario

Estufas de pellet
Ocultar thumbs Ver también para EXTRA:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

FIRST LOAD

This function allows to ll the auger, facilitating the phases of the rst start-up of the stove, or in the
event that the pellet tank is empty.
With the stove cold and "OFF", make sure the pellet has been introduced inside the tank and activate
the FIRST LOAD function, con rming with OK.
To interrupt the loading in continuous, simply press the key
To set: OK > SETTINGS > FIRST LOAD.
ALWAYS REMEMBER TO EMPTY THE BURNING POT COMPLETELY BEFORE TURNING ON AND THAT THE HOLES OF THE
BURNING POT ARE ALL FREE. NEVER EMPTY THE BURNING POT INTO THE PELLET TANK, RISK OF FIRE!

DELTA T

This function allows to set the hysteresis for the shut-down of the stove DELTA T OFF
( set temperature + hysteresis Delta T OFF) and to turn the stove back on (set temperature - hysteresis
Delta T ON), if it is not managed by an external thermostat.
The Delta T ON/OFF range is: 0.5 - 5°C
To set: OK > SETTINGS > DELTA T

RESET

Allows the user to reset all modi able values to the default values.
To set: OK > SETTINGS > RESET.

ADDITIONAL FUNCTIONS

AUX

If conveyor accessories of the manufacturer are used , the connection must be made by a quali ed technician.
Contact the dealer for further details

ADDITIONAL THERMOSTAT

N.B. : Installation must be performed by an authorised technician
There is a possibility to thermostat a room adjacent to the room where the stove has been placed; simply connect a thermostat following the
procedure described in the following section (it is advisable to place the optional mechanical thermostat at a heigh from the ground equal to
1.50m). The operation of the stove with the external thermostat connected to the terminal TA can be di erent depending on the activation or
deactivation of the STAND BY function.

ADDITIONAL THERMOSTAT INSTALLATION

Š Switch the appliance o using the master switch positioned
on the rear of the stove.
Š Remove the plug from the socket.
Š Connect the two cables of the thermostat on the terminal
(TA) behind the machine.
FOR
CORRECT
TEMPERATURE TO LOW-TA
76
OK
OPERATION,
SET
THE
ROOM
for 3 seconds.
ENGLISH

Publicidad

Tabla de contenido
loading

Tabla de contenido