POWER SUPPLY INSTALLATION
I
nstalling the TF-104 transformer.
3,5 x 25
DIN-7971
The transformer can be installed on a DIN guide (3 units) simply pressing it.
To disassemble the transformer from the DIN guide, use a plain screwdriver to lever
the flange as shown on the picture.
DOOR PANEL INSTALLATION
E
mbedding box positioning.
1650
The upper part of the module should be placed at 1,65m. height roughly.
The hole dimensions are: 125(W) x 257(H) x 57(D) mm.
The module has been designed to be placed under most of the environmental conditions.
However it's recommended to take additional cautions like rainproof covers.
The transformer must be installed in a dry and
protected place. It's recommended to protect
3,5 x 25
the transformer by using a thermo-magnetic
DIN-7971
circuit breaker.
To install the transformer directly on the wall,
insert the fixing flanges.
Drill two holes of Ø6 mm. and
insert the wallplugs.
Fix the transformer with the specified
screws.
DIN 46277
1850
1450
42