TERMINAL BOARD CONNECTIONS
Terminals
Function
Description
1 + 2
POWER SUPPLY POWER input 230/115 V AC 50-60 Hz.
FLASHING LIGHT Output FLASHING 230/115 VAC 50 W max. DIP6=ON fixed output during the operation, DIP6=OFF
3 + 4
FLASHING LIGHT
intermittent output during the operation, the flashing frequency is doubled during closing;
7 + 10
OPEN/CLOSE
OPEN/CLOSE input (Normally Open contact);
8 + 10
STOP
STOP input (Normally Closed contact);
PHOTOCELLS OR SAFETY DEVICES input; active during closure (Normally Closed contact); the gate will stop during clos-
9 + 10
PHOTOCELLS
ing and totally reopen it, (10= Common).
24V AC
11 + 12
24 V AC 10 W output to Photocells, Receivers etc.; connect a up to 3 pair of photocells. 11= 0 V AC, 12= 24 V AC;
PHOTOCELLS
13 + 14
AERIAL
433,92 MHz built-in RX aerial input; 13= EARTH, 14= SIGNAL;
Quick coupling for LIMIT SWITCH connection (Normally Closed
M2
LIMIT SWITCH
ORANGE= Closing Limit Switch (CLS), RED= Opening LimitSwitch (OLS), GREY= Common (COM);
FS1 + FS2
CAPACITOR
CAPACITOR Terminals for motor start-up;
Quick coupling for 230 V AC single-phase MOTOR
M3
MOTOR
BROWN= closing (M-CL); BLACK= opening (M-OP).
LOGIC ADJUSTMENTS
TRIMMER
Motor torque adjustment. Turning the trimmer clockwise (+) the torque will be increased; Turning the trimmer counterclockwise (-) the
FR.
torque will be decreased.
Note: The trimmer is set to provide sufficient thrust to work the gate within the limits established by current standards (EN 12453).
Obstacle detection
setting. Turning the trimmer clockwise (+) the sensitivity will be increased; Turning the trimmer counterclockwise (-)
SENS.
the sensitivity will be decreased.
Note: Before setting the obstacle detection, let the gate operator perform a complete opening and closing cycle.
Automatic closing time adjustment. Turning the trimmer clockwise (+) time will be increased; Turning the trimmer counterclockwise (-) the
T.C.A.
time will be decreased.
Note: The time values can be set between 1 and 120 seconds.
Dip switch
On automatic closing enabled.
AUTOMATIC
1
CLOSING
Off automatic closing disabled.
On
(with Automatic closing enabled) Two-Stroke operation mode OPEN-CLOSE, OPEN-CLOSE,
2
2 / 4 STROKE
(with Automatic closing enabled) Four-Stroke operation mode OPEN-STOP-CLOSE-STOP, OPEN-STOP-CLOSE-STOP,
Off
etc.
Turning DIP3 ON, the setting of the travel with slowdown is activated (see following paragraph). At the end of the pro-
On
cedure, leave the dip ON if you want to keep the values obtained. If you turn it OFF and then back ON, the SETUP
3
SOFT-STOP
procedure must be repeated.
Off
The working time is determined by the limit switches, no slowdown. Non-adjustable maximum working time set at 96 seconds.
On
Left-hand leaf opening mode;
OPENING
4
DIRECTION
Off
Right-hand leaf opening mode;
On While opening and during the T.C.A., the gate ignores the closing commands (NO REVERSE);
5
T.C.A
Off The gate behaves as per the setting of dip-switch 2;
On Fixed output during the manoeuvre;
OPERATION OF
6
FLASHING OUTPUT
Off Intermittent output during the manoeuvre, the flashing frequency is doubled during closing;
SOFT-STOP SETTING
Set DIP3 to ON, active procedure (DL1 flashing) - Start with the sliding gate open
Close the AP/CH contact or press the OP/CL pushbutton: the operator will start closing the gate until the Closing Limit Switch (CLS) is reached.
Once the Closing Limit Switch (CLS) is reached, the operator will reverse the cycle and start opening the gate:
1_ Close the AP/CH contact or press the OP/CL pushbutton when the desired start point of the Soft-stop is reached;
2_ Once the Opening Limit Switch (OLS) is reached, the gate will stop. DL1 LED will turn ON (start point set);
3_ If the STOP contact is opened the procedure is interrupted, the gate will stop and DL1 LED will flash to advise that the procedure is still active
(Close the AP/CH contact or press the OP/CL pushbutton to restart the procedure from the beginning).
Note: SOFT-STOP settings apply both to opening and closing.
ATTENTION: to modify the SOFT-STOP settings it is necessary to repeat the whole procedure.
K100M FEATURES
DL1 LED
Other than indicating the programming of a transmitter is going on, DL1 LED advises error messages as follows:
Steady light:
Normal operation;
Fast flashing:
Soft-Stop learning procedure activated;
Slow flashing:
Automatic 50 / 60 HZ Frequency Detection Error;
Contact Technical Service;
6 flashes:
obstacle present after 3 closing attempts;
Make sure the gate slides smoothly and without obstacles in both directions;
7 flashes:
No learning procedure executed;
Perform learning procedure.
8 flashes:
No motor signal;
Check wiring - Make sure the motor can rotate freely;
EARTH,
1= NEUTRAL, 2= PHASE;
If there is more than one safety device, connect all the NC contacts IN SERIES.
contacts).
connection. BLUE= common (M-COM);
etc.
Multiple errors are indicated by a 2" pause between error messages. Messages will be shown until a complete opening/closing cycle is performed.
In the event of 3 consecutive activations (during the same closing manoeuvre) of the amperometric control (obstacle detection), the control unit opens
completely on the next manoeuvre. To reset, the automation must complete a manoeuvre (opening and then closing); otherwise the end stop search pro-
cess will be repeated after each activation of the amperometric control.
In the event of activation (during the opening manoeuvre) of the amperometric control (obstacle detection), the control unit closes approx. 20 cm. stopping
the automation.
On the next manoeuvre
the control unit closes completely.
WARNING: the control panel logics may interpret mechanical friction as an obstacle.
ADVANCED FUNCTIONS
Clock function: a timer can be connected to the open-close pushbutton in order to keep the gate open at certain times during the day, after which it reverts
to automatic closing.
Note: The gate remains open as long as the OP/CL input continues to be activated.
433.92 MHz BUILT-IN RADIO RECEIVER
The built-in radio receiver can store up to 30 different codes from Rolling Code transmitters (BUG2R, BUG4R, K-SLIM-RP, T-4RP).
The radio channel directly commands the control board for opening the automatic device.
LEARNING PROCEDURE FOR TRANSMITTERS
REMOTE CONTROL LEARNING = OPENS/CLOSES
RADIO+OP/CL = PEDESTRIAN
1_ press and release the RADIO button on the control unit;
2_ DL1 LED turns OFF to indicate that the programming mode has been activated (if no code is entered within 10 seconds, the control unit will exit the
programming mode);
3_ press and release the transmitter button;
4_ DL1 LED turns ON again to indicate that the new code is stored (if this does not happen, wait 10 seconds and start again from point 1);
5_ to store other transmitters, repeat the procedure from point 1 up to a maximum of 30 transmitters;
6_ if you wish to store the pedestrian control, repeat the procedure in point 1 pressing the RADIO+OP/CL 1 keys together instead of the RADIO key;
7_ to exit the programming mode without storing a code, press and release RADIO button.
Note: When the maximum number of transmitter (30) is reached, the DL1 LED will start flashing fast for about 3", without performing memo-
risation.
REMOTE PROGRAMMING THROUGH T-4RP and K-SLIM-RP (V 4.X)
With the V 4.X software version it is possible to carry out remote learning with remote controls T-4RP and K-SLIM-RP (V 4.X), that is without acting directly
on the programming keys of the receiver.
It will be sufficient to have an already programmed remote control in the receiver and you will be able to open remote programming of the new remote
controls. Follow the procedure in the instructions of the T-4RP and K-SLIM-RP (V 4.X) remote controls.
ERASING ALL PROGRAMMED TRANSMITTERS
1_ press and hold the RADIO button on the control unit for approx. 3" to start the erasing procedure;
2_ DL1 LED flashes slowly to indicate that the erasing procedure has been activated;
3_ again, press and hold the RADIO button on the control unit for approx. 3";
4_ DL1 LED turns off for approx. 3", then turns ON To indicate that all stored codes have been cancelled;
5_ repeat the procedure in point 1 using the RADIO+OP/CL keys together to cancel all the controls associated with the PEDESTRIAN control;
6_ to exit the erasing mode, press and release RADIO button.
RADIO MEMORY HARD RESET:
-
press without releasing keys RADIO+OP/CL till LED DL1 starts flashing quickly. At this point release the keys and press them again till the LED go off
and on again, confirming the operation is complete.
RADIO MEMORY WRITING VIA TAUSOFT
To enable writing the radio memory with TAUSOFT, keep keys RADIO+OP/CL pressed while you connect the cable to connector "SM" of K100M and keep
them pressed until DL1 stops flashing. For information regarding radio programming with TAUSOFT, refer to the relative manual.
TROUBLESHOOTING GUIDE
Operator does not run
a- Check 230/115 V power supply with a voltmeter;
b- Check that all 4 green LEDs (Normally Closed contacts, DL3, DL4, DL5 and DL6) are ON, and that DL2 LED (Normally Open contacts) is OFF.
LED DL1 must be ON;
c-
Check that the red DL1 LED is ON;
d- Check that the fuses are intact with a voltmeter.
The radio control has little range
a- Check that the ground and the aerial signal connections have not been inverted;
b- Do not make joints to increase the length of the aerial wire;
c- Do not install the aerial in a low position or behind walls or pillars;
d- Check the state of the transmitter's batteries.
The gate opens the wrong way
a_ Invert the position of DIP 4 (after having turned off the power to the control unit).