If Something Fails To Work - Teka SL P60 4G AI AL Instrucciones Para La Instalación Y Recomendaciones De Uso Y Mantenimiento

Encimeras de cocción
Ocultar thumbs Ver también para SL P60 4G AI AL:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN

If something fails to work

Before calling the Technical Service, please make the following checks:
Fault
Neither the hotplates nor the pilot lights are working.
There is no spark when the automatic ignition control is pressed.
There is a spark but the burner is not igniting.
The gas burners do not light.
The burner ignites but, when you stop holding down the knob that activates the safety feature, it goes out
again.
The gas burners are making the pans dirty
45
Possible cause
The cable is not connected to the
mains.
There is no current at the plug.
The spark plug and the part of the
burner where the spark should be
is soiled or greasy.
Gas is not coming through to the
hob.
The flame is not appearing in the
area heated by the thermocouple.
The burner openings are dirty.
The injector or injector holder is
dirty.
Possible solution
Connect the cable to the network
Check/repair the electricity at the
mains.
Clean the end of the spark plug
and the burner.
Check that the gas cylinder tap is
properly open
If it is piped gas, open the gas tap.
Clean the burner's openings
Clean the burners' openings.
Clean the injector holder and
injector without using any-thing
which could damage or alter the
diameter
of
the
opening.
.
gas
outlet