Powering the Detector

1. Insert three "AA" batteries into the battery
holder while verifying polarity. Refer to Figure
2 on page 27.
2. Insert the battery holder into the back cover
and affix the battery cable to the battery
connector on the PCB. Refer to Figure 3 on
page 28.
After connecting the battery cable, a power-up
sequence will begin (lasting between 10 to 30
seconds). During this time, the red LED will
flash and the detector will not detect an open
zone or tamper.

Replacing the Batteries

1. Disconnect the battery cable from the battery
connector of the PCB.
2. Remove the battery holder from the back
cover and remove the old batteries.
3. Press and release the tamper switch to
ensure that the unit has powered down.
4. Follow the steps outlined in Powering the
Detector above.

Sensitivity Settings

MG-PMD85 features adjustable sensitivity.
Adjust from 1 to 10 where 1 is the lowest setting
and 10 the highest. Remove the front cover and
with a screwdriver, turn the trimpot clockwise to
increase the detector's sensitivity or
counterclockwise to decrease it.