5.1 Electrical and electromagnetic specifications
Power supply: 24Vac/dc, ±10%
Power consumption: max 1.5W
Temperature range: -20°C / +70°C
Max humidity: max 95%
Loop inductance range: 25µH / 800µH
Frequency range: 30kHz / 130kHz
Sensitivity range: (∆F/F): 0.01% / 0.65% in 4 steps
Loop lead-in: max 250m
Output relays:
1 presence relay with contact n.c.
1 pulse relay with contact n.a.
adjustment of rest or operation current principle for permanent relay with shift switch on front plate
Switch voltage: 24Vac/dc
Housing: Plastic-clamp enclosure for shelf or DIN-rail socket with 2x3-pin clamps
Dimensions: 79x22,5x90mm
Protection class: IP 40 (waterproofed)

5.2 Terminal connection

Terminal screws on top
Signature
Function
0V
Power supply (neutral)
24V
Power supply (24Vac/dc)
28V
Contact n.o. 2- pulse relay
Terminal screws on bottom
Signature
Function
16
Contact n.c. 1 presence relay
15
Common 1 presence relay
25
Common 2 pulse relay
5.3 Dip- switch modes
1
2
3
OFF
OFF
-
ON
OFF
-
OFF
ON
-
ON
ON
-
-
-
OFF
-
-
ON
-
-
-
-
-
-
(OFF= Left switch position)
(ON= Right switch position)
5.4 Loop connector with adjustment of frequency step - Function of led's
Led green
Led red
Off
off
Flash
off
On
off
On
on
Off
Pulse
Pulse
-
6
4
Function
-
Sensitivity - step 1 (low)
-
Sensitivity- step 2 (med-low)
-
Sensitivity- step 3 (med-high)
-
Sensitivity- step 1 (high)
-
Holding time 5 minutes
-
Holding time unlimited
OFF
Principle of rest current
ON
Principle of operation current
Function
Power off
Detector calibrates
Detector ready for operation, loop free
Detector ready for operation, loop occupied
Loop failure
Loop frequency by pulse signal