Troubleshooting - GYS STARTIUM 330E Manual Del Usuario

Ocultar thumbs Ver también para STARTIUM 330E:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING

Troubleshooting
Error LED flashed
Error LED flashes and alarm beep
The LEDs won't light up
In START ENGINE mode, if the screen
displays 0%. Restart impossible
The electrolyte is boiling
10
STARTIUM 330E / 480E / 680E
Causes
Power supply issue.
Clamps in short-circuit or polarity
reversal.
The battery is faulty.
Voltage error (12 -24 V)
Battery not detected or <1V. Display :
«BAt HS»
After an intensive use the device goes
to thermal protection. Display : «th»
Power supply issue.
The internal fuse has blown
The On/Off switch isn't engaged.
The battery is sulphated, starting the
battery is prevented to protect the
vehicle electronics.
The voltage selected isn't correct
(12V or 24V).
The battery has an element in short-
circuit.
Remedies
Check the power supply.
Check if the fuses have blown
Do not put the clamps in short-circuit.
Reverse the polarity.
Check the voltage at the battery
terminals with a voltmeter. If the
voltage instantaneously increase
by more than 2.5V by element the
battery can be sulphated or damaged.
Check the battery is connected on 12
or 24V.
Connect the battery.
Select TIMER if the battery voltage is
<1V.
Wait 1/4h for the device to cool
down.
Check the power supply.
Return the device back to GYS after-
sales.
Switch the ON/OFF button.
Recharge the battery prior using
START ENGINE.
Check the battery voltage and
connect it correctly.
The battery cannot be recovered, it
must be replaced.