TECHNICAL DATA
Sub-Scanner
Metal Mode depth accuracy .........................................................
Metal Mode center accuracy ........................................................
Drywall Mode center accuracy .....................................................
Operating temperature .................................................................
Storage temperature.....................................................................
Battery life (with all functions) .......................................................
Voltage Battery .............................................................................
Weight according EPTA-Procedure 01/2003 ................................
WARNING! Read all safety warnings and all
instructions, including those given in the accompanying
brochure. Failure to follow the warnings and instructions may
result in electric shock, fire and/or serious injury.
Save all warnings and instructions for future reference.
SAFETY INSTRUCTIONS
Avoid dangerous environments. Do not use in rain, snow, damp
or wet locations. Do not use in the presence of explosive
atmospheres (gaseous fumes, dust or fammable materials)
because sparks may be generated when inserting or removing
battery pack, possibly causing fire.
Do not dispose of used battery packs in the household refuse
or by burning them. Milwaukee Distributors offer to retrieve old
batteries to protect our environment.
Do not store the battery pack together with metal objects (short
circuit risk).
Use only System C 12 chargers for charging System C 12
battery packs. Do not use battery packs from other systems.
Battery acid may leak from damaged batteries under extreme
load or extreme temperatures. In case of contact with battery
acid wash it off immediately with soap and water. In case of eye
contact rinse thoroughly for at least 10 minutes and
immediately seek medical attention.
This appliance is not intended for use by persons (including
children) with limited physical, sensory or mental capabilities or
insufficient experience and/or knowledge unless they are
supervised by a person who is responsible for their safety or
have been instructed by them in the safe use of the tool.
Children should be supervised in order to ensure that they do
not play with the tool.
The LED may not be displayed due to installation condition of
electrical circuit or equipment. Never touch the circuit under
test to avoid possible danger even if the LED for NCVD is not
displayed. Check the functionality of LED on a well-known
power supply prior to measurement. When the LED doesn't
light up, do not make measurement. NCVD indication is
affected by external voltage, and how the meter is held or
placed.
SPECIFIED CONDITIONS OF USE
In metal mode, the Sub-Scanner will detect both ferrous
(>14 mm Ø) and non-ferrous (>16 mm Ø) metals in concrete up
to a depth of 15.2 cm, regardless of the wall texture.
In drywall mode, the Sub-Scanner will detect wood or metal
studs and joists behind wall board, wooden panels, or other
homogeneous materials, e.g. chipboard and oriented strand
board.
In this mode, additionally to wood and metal objects, other
objects detected, such as water-filled plastic pipe or copper
tube.
Do not use this product in any other way as stated for normal
use.
BATTERIES
New battery packs reach full loading capacity after 4 - 5
chargings and dischargings. Battery packs which have not
been used for some time should be recharged before use.
14
ENGLISH
C 12 WS
..................... ±1.3 cm(1.3 cm - 15.2 cm)
..................... ±1.3 cm (1.3 cm - 15.2 cm)
..................... ±1.3 cm (1.3 cm - 3.8 cm)
............ -5°C ... 40 °C
.......... -20°C ... 60 °C
...................... >12 h
........................ 12 V
...................... 722 g
Temperatures in excess of 50°C (122°F) reduce the
performance of the battery pack. Avoid extended exposure to
heat or sunshine (risk of overheating).
The contacts of chargers and battery packs must be kept clean.
For an optimum life-time, after use, the battery packs have to
be fully charged.
To obtain the longest possible battery life remove the battery
pack from the charger once it is fully charged.
For battery pack storage longer than 30 days:
Store the battery pack where the temperature is below 27°C
and away from moisture
Store the battery packs in a 30% - 50% charged condition
Every six months of storage, charge the pack as normal.
WORKING TIPS
The Sub-Scanner can not reliably detect metal or studs behind
material of varying densities. Materials such as carpet, wire
metal mesh backing, damp walls, and stucco may affect
readings. Alternating surfaces, such as thick grout lines or
extremely heavy plaster on drywall, may be detected or show
as metal or studs.
If calibration error is displayed
flashing, move the
Sub-Scanner to another position and restart calibration.
In case the stud sensor can't calibrate everywhere on the
drywall or in the air, probably the unit is damaged.
The Sub-Scanner will not calibrate correctly over studs. To find
a location without studs, locate an outlet box and move the
Sub-Scanner 15 cm to either side before beginning calibration.
When SCANNING is displayed, move the Sub-Scanner across
the surface. Keep your free hand and other objects at least
15 cm away to avoid false readings.
If electric wires or metal/pipes are in contact with the backside
of the wallboard, they may be identified as a stud.
Use the METAL mode to scan for conduit.
SLEEP MODE
The Sub-Scanner is automatically powered off in about 20
minutes after the last operation. To reset, press any button. If
the display is blank when the Sub-Scanner is turned ON,
charge the battery according to the battery/charger manual.
The Sub-Scanner does use battery power in sleep mode. Be
sure to turn OFF the tool to conserve battery power.
MAINTENANCE
Clean the laser windows with a soft, moist cloth to keep them
clean and clear. Remove battery before cleaning.
Warning!
To reduce the risk of personal injury and damage, never
immerse your tool in liquid or allow a liquid to fow inside it.
Clean dust and debris from tool. Keep tool handles clean, dry
and free of oil or grease. Use only mild soap and a damp cloth
to clean the tool since certain cleaning agents and solvents are
harmful to plastics and other insulated parts. Never use
flammable or combustible solvents around tools
Use only Milwaukee accessories and Milwaukee spare parts.
Should components need to be replaced which have not been
described, please contact one of our Milwaukee service agents
(see our list of guarantee/service addresses).
If needed, an exploded view of the tool can be ordered. Please
state the Article No. as well as the machine type printed on the
label and order the drawing at your local service agents or
directly at: Milwaukee Electric Tool, Max-Eyth-Straße 10,
D-71364 Winnenden, Germany.
SYMBOLS
Please read the instructions carefully before
starting the machine.
Remove the battery pack before starting any
work on the machine.
Do not dispose of electric tools together with
household waste material! In observance of
European Directive 2002/96/EC on waste
electrical and electronic equipment and its
implementation in accordance with national law,
electric tools that have reached the end of their
life must be collected separately and returned to
an environmentally compatible recycling facility.