General Specifications - Klein Tools Ranger TDR Manual De Instrucciones

Medidor de longitud de cable. localizador de fallas en cable. generador de tonos. administrador de cable
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH
The Klein Tools Ranger™ TDR is a portable time domain refl ectometer
(TDR) and voice-data-video cable tester. It measures cable length,
calibrates Nominal Velocity of Propagation (NVP) values, fi nds faults in
cables, and provides built-in tone generation for cable tracing.
• ±1% and ±3 ft (1 m) length accuracy.
• Stores up to two NVP values.
• Displays length reading in feet or meters.
• Extra large seven-segment, back-lit LCD screen.
• Tests most types of copper cable including data, voice, video, lamp
wire, siamese, and NM cables.
• Discovers NVP values for cables with known length.
• Automatic pre-test voltage checks.
• Identifi es cable faults.
• Tone generator with selectable tone cadence to easily trace cables
with an analog tone probe (not included).
• Conserves power and supports long battery life with auto power off.
• Dimensions: 6.8" x 3.15" x 1.3" (17.3 x 8.0 x 3.3 cm)
• Weight: 12.0 oz. (340 grams) with batteries
• Operating Temperature: 0°C / 32°F to 50°C / 122°F
• Storage Temperature: -20°C / -4°F to 60°C / 140°F
• Humidity: 10% to 90%, non-condensing
• Altitude: 10,000 ft (3,050 m) maximum
• Input Protection: 400V peak 50/60Hz AC or DC
• Voltage Warning: At maximum of Safety Extra Low Voltage
limits (60V peak AC or DC). Measurement continues while
warning is displayed.
• Battery Low Level: Approximately 4V
• Battery Life: 4 AA alkaline batteries
• Standby: 4 years
• Active: 15 hours (average)
• Measurement Method: Spread Spectrum Time Domain Refl ectometry
• NVP (VOP) Range: 20.0 to 99.9%
• NVP Accuracy Range: ±1% and ±3 ft (1 m) with known NVP and
consistent cable parameters
• Common Cable Length Ranges:
• Coaxial: 0 to 2,000 ft
• Data: 0 to 1,500 ft
• Electrical: 0 to 1,000 ft
• Tone Generation: Constant output amplitude of 3Vpp, 4 cadences
centered around 1 kHz