INSTALLATION AND SERVICE INSTRUCTIONS FOR FEDERAL MODEL 27XST
SAFETY MESSAGE TO INSTALLERS, USERS AND MAINTENANCE PERSONNEL
It is important to follow all instructions shipped with this product. This device is
to be installed by a trained electrician who is thoroughly familiar with the National
Electrical Code and/or Canadian Electrical Code and will follow the NEC and/or CEC
Guidelines as well as local codes.
This device should be considered a part of the warning system and not the entire
warning system. The selection of the mounting location for the device, its controls and
the routing of the wiring are to be accomplished under the direction of the facilities
engineer and the safety engineer. In addition, listed below are some other important
safety instructions and precautions you should follow:
Read and understand all instructions before installing or operating this
equipment.
Never alter the unit in any manner. Safety may be compromised if ad-
ditional openings or other alterations are made to the unit.
Do not connect the equipment when the circuit is powered or if the loca-
tion is not known to be free of concentrations of ignitable concentrations.
After installation, ensure that the set screw and threaded joints are
properly tightened.
After installation, test the light system to ensure that it operating prop-
erly.
After testing is complete, provide a copy of this instruction sheet to all
operating personnel.
Establish a procedure to routinely check the light installation for integ-
rity and proper operation.
Keep the unit tightly closed when in operation.
Failure to follow all safety precautions and instructions may result in property
damage, serious injury, or death.
I.
GENERAL
This equipment is suitable for use in Class I, Div. I, Groups C and D; Class I, Div. 2,
Groups A, B, C and D; Class II, Div. 1, Groups E, F, and G; Class III, or non-hazardous
locations only.
The Model 27XST strobe light is a visual signaling device for hazardous locations and
provides about 75 to 80 high-intensity flashes per minute. The effective candlepower
(ECP) of the light is 850 candelas (clear dome). The unit is UL and CSA listed for
indoor and outdoor use and has been found to comply with Type 4X (watertight and
corrosion resistant) enclosure requirements and Marine Visual Signal Device, Outside
Type (saltwater).