Cabling diagram for the SRL18 torch.
Torch 2 triggers + poten-
tiometer

REMOTE CONTROL

The remote control operates in TIG mode and in MMA.
ref. 045699
Connections:
1- Plug the remote control into the connection at the back of the machine.
2- The machine will detect automatically the remote control and open a selection menu:
3- Select the remote control type
Connection
The machine is equipped with a female socket for remote control. The specific 7 pin male plug (optional ref.045699) enables connection to a
manual remote control or foot pedal. For the cabling layout, please see the diagram below.
CONNECT-5
Operating :
• Manual remote control (option ref. 045675)
The remote control enables the variation of current from 50% to 100% of the set intensity In this configuration, all modes and functions of the
machine are accessible and can be set.
• Foot pedal (option ref. 045682) :
The pedal control enables variation of the current from the minimum current to 100% of the set intensity.
In TIG, the welding machine only operates in 2T mode. The upslope and downslope are not automatically managed by the current source, and are
controlled by the user with the foot pedal.
30
TIG 220 AC/DC
Torch type
Torch 2 triggers
G
F
A
E
B
D
C
External view
REMOTE CONTROL TYPE
Foot pedal
Torch 1 trigger
D
045682
C
B
045675
A
Electric diagram according to the remote control type.
Manual remote control
Electric diagram according to torch type.
Wire description
Common/Earth
Trigger 1
Trigger 2
Common/Potentio-
meter earth
VCC
Cursor
Wire description
VCC
Cursor
Common/Earth
Switch
AUTO-DETECT
ARC ON
REG I
EN
Pin
2 (green)
4 (white)
3 (brown)
2 (grey)
1 (yellow)
5 (pink)
Pin
A
B
C
D
E
F
G

Publicidad

Tabla de contenido
loading

Tabla de contenido