MECHANICAL MONITOR ATTACHMENT
The.Monitor.is.to.be.mounted.on.the.waterway.with.eight.5/8.inch.bolts.and.nuts.of.grade.five.minimum.and.suitable.washers.with.
a.minimum.of.six.threads.engagement . . The.front.of.the.monitor.in.Figure.2.is.considered.to.be.point.4.and.is.above.the.identification.
tag . . The.bolts.must.be.tightened.in.a.criss.cross.pattern.progressively.increasing.tightening.torque.to.a.maximum.of.100.foot.
pound.dry .
NOTE:..Not.recommended.to.mount.on.a.raised.flange.or.have.a.butterfly.valve.between.the.flanges . . This.may.cause.damage.to.the.
monitor's.flange.when.tightening.the.bolts .
THE.ROTATIONAL.AND.ELEVATION.STOPS.SET.THE.BOUNDARIES.FOR.THE.AREA.IN.WHICH.THE.MONITOR.IS.
ALLOWED.TO.TRAVEL.AND.MEETS.THE.REQUIREMENTS.OF.THE.NFPA . . The.upper.row.controls.the.right.travel,.and.the.lower.row.
controls.the.left.travel . . The.angles.for.the.rotational.stops.are.with.respect.to.the."reference.direction".illustrated.in.Figure.2 . . The.
monitor.is.shipped.with.the.upper.row.stop.at.point.3.which.stops.the.monitor.at.90˚.right,.clockwise.and.the.lower.row.stop.at.point.
5.which.stops.the.monitor.at.90˚.left,.counterclockwise . . All.other.positions.are.achieved.by.switching.the.factory.set.stops.and.the.
plugs.in.the.desired.stop.location . . Both.the.stops.and.the.plugs.have.a.1/2.inch.hex.head . . Refer.to.Figure.2.to.determine.which.stop.lo-
cation.is.needed.for.the.desired.right,.clockwise.or.left,.counterclockwise.rotation . . The.elevation.stop.sets.the.upper.and.lower.limits.
of.the.elevation . . The.monitor.is.shipped.with.the.upper.limit.at.45°.or.90°.above.horizontal.(mounted.vertically).and.the.lower.limit.at.
45°.below.horizontal.to.meet.NFPA . . All.other.vertical.positions.are.achieved.by.switching.plugs.and.stops.to.the.desired.locations.as.
indicated.in.Figure.4 .
MECHANICAL ATTACHMENT OF CONTROLLER AND LOGIC BOX
A . . CONTROLLER.AND.TETHER.CONNECTOR.ATTACHMENT
Pump.panel.cut.out.and.mounting.hole.dimensions.are.given.in.Figure.3 . . .The.controller.and.tether.connector.should.be.installed.in.
the.pump.panel.prior.to.electrical.connection.to.the.logic.box .
B . . LOGIC.BOX.ATTACHMENT
The.StreamMaster.logic.box.must.be.mounted.close.enough.to.the.monitor.to.allow.the.8.ft . . monitor.wiring.harness.sufficient.slack.
to.allow.the.monitor.to.travel.through.its.full.range . . The.logic.box.overall.dimensions.and.mounting.hole.dimensions.are.given.in.
Figure.5 .
WARNING:..Do.not.extend.the.monitor.wiring.harness .
ELECTRICAL INSTALLATION INSTRUCTIONS
A . .
CONTROLLER,.JOYSTICK.OR.TETHER.CONNECTOR.ELECTRICAL.ATTACHMENT
These.instructions.are.for.attaching.the.controller,.joystick.or.the.tether.connector.to.the.logic.box . . .The.controller,.
joystick.and.tether.connector.are.supplied.with.8.ft . . of.cable .
STEP 1. If.the.control.box.includes.an.attached.cable.skip.to.STEP.6 .
STEP 2. Determine.the.length.of.#20-7.cable.needed,.add.10.inches,.then.cut . . For.example,.if.a.five.foot.length..
.
of.cable.is.needed,.add.10.inches.and.cut.the.cable.5.foot.10.inches.long .
STEP 3 . Remove.the.cable.grip.nut.and.washer.from.the.control.box.and.put.it.on.the.cable.with.the.threads.
.
facing.the.box . . On.the.same.end.of.the.cable.remove.4.inches.of.the.outer.casing.of.the.cable.and.strip..
.
back.3/8.inch.from.each.of.the.7.wires .
STEP 4 . Take.the.7.ring.terminals.from.the.plastic.bag.and.crimp.them.on.the.7.wires . . Remove.the.four.control
.
box.cover.screws.and.set.the.control.box.cover.aside . . Thread.the.7.wires.through.the.cable.grip.
.
attached.to.the.control.box.and.attach.them.to.the.proper.terminals . . Tighten.the.cable.grip.nut.and..
.
washer.on.the.cable.to.the.cable.grip.on.the.control.box.to.secure.the.cable . . Reattach.control.box.cover.. .
.
and.secure.with.the.four.screws . .
STRAIGHT
WHITE
WHT
FOG
Page.3
.
.
.
RIGHT
RAISE
WHT
LEFT