EKKO
User Manual
Manual unlocking: open the cover, insert the release key, turn it anticlockwise and close the cover. The gate leaf can be pushed manually.
Resetting the automatic operation: move the gate into the fully closed position, open the cover, insert the release key, turn it clockwise and close the cover.
After a command, the gate will open.
- In the event of mains power failure, the back-up battery ensures the operation of the automatic gate system for a limited period. In the event of a flat or
missing battery, manually unlock the actuator, it is advisable to move the gate into the fully open position and reset unlocking by turning the key clockwise
and close the cover, which is to prevent any unwanted movement of the gate (with the actuator unlocked the gate leaf is free to move, which could cause
damage to property or persons).
Once the power supply is restored, the electronic board will charge the back-up battery and the gate will return to normal operation after a command pulse.
CAUTION: Unlock and reset with the gate stationary.
Maintenance: Periodically check the fixing screws, the integrity of the connecting cables, the correct functioning of the safety systems (photocells and
sensitive edges), the robustness of the mechanical stops and the soundness of the systems for supporting the gate leaf (hinges or bearings). Every 2 years
it is recommended to replace the batteries in the remote control.
Location of the buttons for controlling the gate (selectors, keypads, buttons, etc.)
Control device
Association of the remote control buttons
Button
Not used
Button 1
Button 2
If the automatic closing function is active (when the gate is stationary and open the flashing light stays on) the
gate closes after the set time. You can disable this function by pressing the button on the remote control before
the gate reaches the fully open position. If the sequential function is active it opens-stops-closes.
If the gate meets an obstacle on closing, and automatic closing is active, the control unit makes 5
attempts at closing, after which it remains open. In this case it is necessary to remove the obstacle from
its path and control the gate with the transmitter and button so that it closes completely at low speed.
14
Controls total opening of the gate
Location
Controls partial opening of the gate
Controls second channel
output
button 1
button 2
EN