Aprimatic T3 Instrucciones Para La Instalación página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

Device fitted with Aprimatic microprocessor designed to drive 2 motors with a maximum
power of 250 Watt each. Absorption in stand- by: 15 W.
1.1 BLOCK DIAGRAM OF THE DEVICE
RV1
Approach speed trimmer
RV2
Reverse sensitivity trimmer
RV3
Pause time trimmer
RV4
Operating time trimmer
F1
Motor 5A fuse
F2
Network protection 200 mA fuse
F3
Accessory 24V output 500 mA fuse
SW1 DIP-SWITCHES
K1
Motor terminal board + mains voltage (IN)
K2
Signal/command terminal board
K3
Aprimatic exclusive accessory connection terminal
K4
Earth connection terminal board
K5
Courtesy light connector
RL3
Courtesy light relay
RL5
Motor relay
RL2
Direction relay
L5
Start LED relay
L6
Open safety photocell/close command LED
L7
Stop LED
L8
Photocell LED
L9
Limit switch LED
TF1
Transformer
J1
Slowing type
CAUTION - The product must only be installed by qualified servicing and/or installation
personnel.
CAUTION - The electrical system must comply with current regulations in the country
where the product is installed.
CAUTION - Always make sure that the mains power supply is turned OFF before
opening the container. Ensure that there is a good earthing system. Always
connect it to the relative terminals.
= more sensitive = less thrust force
= less sensitive = more thrust force
N.B. If T3 is used with a hydraulic operator, set RV2 at the
end of the scale range towards
Switch S6 to the ON position.
T3.EPS
.

Publicidad

Capítulos

Tabla de contenido
loading