COOLING ONLY MODELS
OPERATING LIMITS
Maximum conditions
Outdoor temperature : 52°C D.B.*
Room temperature
: 35°C D.B. / 22.5°C W.B.
Minimum conditions
Outdoor temperature : 19°C D.B.**
Room temperature
: 19°C D.B. / 14°C W.B.
HEAT PUMP MODELS
OPERATING LIMITS
Cooling Maximum conditions
Outdoor temperature : 46°C D.B.
Room temperature
: 35°C D.B. / 22°C W.B.
Cooling Minimum conditions
Outdoor temperature : 19°C D.B.
Room temperature
: 19°C D.B. / 14°C W.B.
Heating Maximum conditions
Outdoor temperature : 24°C D.B. / 18°C W.B.
Room temperature
: 27°C D.B.
Heating Minimum conditions
Outdoor temperature : –8°C D.B. / –9°C W.B.
PARTS
FIGURE
RAWL PLUG
PLASTIC
COVER
HEX
WRENCH
TAPPING
SCREW 4x30
*
Available only for heat pump models.
as it satisfies Directives:
ACCESSORIES SUPPLIED WITH THE UNIT
Q.TY
PARTS
REMOTE
3
CONTROL UNIT
REMOTE CONTROL
1
UNIT SCREW
AAA ALKALINE
1
BATTERY
DRAIN
4
ELBOW
*
37.4163.129.1
INSTALLATION INSTRUCTIONS
- Split system air conditioner -
Model Combinations
Combine indoor and outdoor units only as listed below.
COOLING ONLY MODELS
Indoor Units
KA96C5
KA127C5
HEAT PUMP MODELS
KA96R5
KA127R5
Power Supply:
220 - 240 V ~ 50 Hz
Tools required for installation (not supplied)
11. Standard screwdriver
12. Phillips head screwdriver
13. Knife or wire stripper
14. Tape measure
15. Level
16. Sabre saw or key hole saw
17. Hacksaw
18. Core bits ø 5
19. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
FIGURE
Q.TY
1
WASHER
1
BRACKET
INSULATING MATERIAL
2
FOR INDOOR UNIT
CONNECTIONS
1
CLAMPER
06/97
Outdoor Units
GR93C5
GR125C5
GR95R5
GR124R5
PARTS
FIGURE
10 11 294 F.GB.I.E.D.01
EG
I
F
D
E
Q.TY
2
1
2
6