Types Of Work; Care And Maintenance - Hilti TE 500 Manual De Instrucciones Original

Ocultar thumbs Ver también para TE 500:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44
5.1.4
Removing the accessory tool
DANGER
Risk of fire! Risk of contact between the hot accessory tool and highly inflammable materials.
▶ Do not lay the hot accessory tool down on highly inflammable materials.
WARNING
Risk of injury! The tool becomes hot as a result of use.
▶ Wear protective gloves when changing the tool.
▶ Pull the chuck back as far as it will go and remove the accessory tool.
Use only the recommended grease supplied by Hilti. Use of unsuitable grease may cause damage
to the product.
5.2

Types of work

WARNING
Risk of electric shock! Severe injury and burns can result if any attempt is made to operate the tool without
an earth/ground conductor and ground fault circuit interrupter correctly connected.
▶ Irrespective of whether mains power or generator power is used, always make sure that an earth/ground
conductor and ground fault circuit interrupter are present in the power supply and that these are correctly
connected.
▶ Do not use the product unless these safety measures are in place and fully operational.
WARNING
A damaged supply cord presents a hazard! Do not touch the supply cord or extension cord if damaged
while working. Disconnect the supply cord plug from the power outlet.
▶ Check the appliance's supply cord at regular intervals and have it replaced by a qualified specialist if
found to be damaged.
Full approval must be obtained from the site engineer or architect prior to beginning the work.
5.2.1
Chiseling
▶ Set the function selector switch to the
6

Care and maintenance

WARNING
Danger of electric shock! Carrying out care and maintenance while the supply cord is connected to the
power outlet presents a risk of serious injuries including burns.
▶ Always unplug the supply cord before carrying out all care and maintenance tasks.
Care
Carefully remove stubborn dirt from the tool.
Clean the air vents carefully with a dry brush.
Use only a slightly damp cloth to clean the casing. Do not use cleaning agents containing silicone as
they can attack the plastic parts.
Maintenance
WARNING
Danger of electric shock! Improper repairs to electrical components may lead to serious injuries including
burns.
▶ Repairs to the electrical section of the tool or appliance may be carried out only by trained electrical
specialists.
At regular intervals, check all visible parts and the controls for signs of damage and make sure that they
all function correctly.
378616
*378616*
Printed: 15.05.2018 | Doc-Nr: PUB / 5070999 / 000 / 09
5
position.
English
17

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Te 500-avr

Tabla de contenido