Memory Deletion; Example Of Level One Programming; Example Of Level Two Programming - Nice Pop Manual Del Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 118

7.2) Memory deletion

Each new programme replaces the previous settings. It is usually
unnecessary to "delete all" the memory. If required, the memory can
be totally deleted by performing this simple operation:
Table "C1"
Delete memory:
1.
Switch the power supply to the control box off, and wait until all the LEDs have gone off
(remove fuse F1 if necessary).
2.
Press P1 and P2 on the board down and keep them pressed down.
3.
Switch the power supply on again.
4.
Wait at least 3 seconds before releasing the two keys
If the memory was deleted correctly, all the Leds will switch off for 1 second.

7.3) Example of level one programming

The following examples show how to activate or deactivate a level one function, the "Condominium" function, for example, and prepare the
"Gate Open Indicator" output in order to activate the electric lock.
Example of level one programming: activate the "Condominium" function and
"Electric lock" output
1.
Access the level one programming mode by pressing P1 and P2, and keeping them pressed
down for at least 3 seconds.
2.
Press P1 once to move the flashing Led to the Led 2 (the flashes will be short)
3.
Activate the "Condominium" function by pressing P2 (the flashes will be longer).
4.
Press P3 once in order to activate part two (the P3 LED will switch on)
5.
Press P1 once to move the flashing Led to the Led 2 (the flashes will be short)
6.
Activate the "Electric lock" output by pressing P2 (the flashes will be longer).
7.
Press P1 and P2 for at least 3 seconds to exit the programming mode and save modifications

7.4) Example of level two programming

This example shows how to modify a level two parameter, for example, how to modify current sensitivity intil "level 5".
Example of level two programming: modifying "current sensitivity"
1.
Access the level one programming mode by pressing P1 and P2 for at least 3 seconds
2.
Press P1 three times to move the flashing Led to the Led 4
3.
Access level two by pressing P2 for at least 3 seconds.
4.
Press P2 three times until Led 5 switches on
5.
Return to level one by pressing P1.
6.
Press P1 and P2 for at least 3 seconds to exit the programming mode and save modifications
!
As all the functions return to their pre-set values after
the memory is deleted, a new search for the mechanical
stops must be carried out.
GB
Example
P1
P2
P1
P2
3s
Example
P1
P2
3s
2
P1
x1
P2
P3
2
P1
P2
P1
P2
3s
Example
P1
P2
3s
4
P1
x3
P2
3s
5
P2
x3
P1
P1
P2
3s
13

Publicidad

Tabla de contenido
loading

Tabla de contenido