Included In Delivery; Installing The Appliance - Gaggenau CMP 250 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Included in delivery

(a)
Fully automatic coffee machine
(b)
Installation instructions
(c)
Assembly bracket
(d)
Spacer
(e)
7 fastening screws (silver)
(f)
2 fastening screws (long/black)
(g)
2 fastening screws (short/black)
(h)
1 sleeve (black)
(i)
2 sleeves (white)
(j)
Transformer fixture
(k)
Transformer
10

Installing the appliance

Make sure there is adequate aeration. To do this,
remove the rear panel or cut out an opening of 19
15
" (500 x 400 mm). There must be a gap of at least
3
4
1
" (35 mm) between the wall and base of the unit or
3
8
the rear panel of the unit situated above. The ventilation
slots and intake openings must not be covered. Also
follow the installation instructions for the appliance
situated above or below. If installing the appliance
above a warming drawer, the height of the recess must
be 23
" (590 mm). If the appliance is installed directly
1
4
under a décor panel, ensure that there is a ventilation
slot of at least 31 square inches (200 cm
installation height for the fully automatic espresso
machine, measured from the floor to the lower edge of
the appliance, is 37
" (950 mm).
3
8
Protect the appliance against freezing or it will be
damaged.
NOTICE: Installation must always be performed by two
persons.
1
Unpack all the parts and check for any damage in
transit. Do not operate a damaged appliance.
2
Take note of the installation dimensions of the
particular model.
Important:
Two opening angles can be selected for
the door. Depending on the opening angle
required, the mounting distance to the wall should
be observed before installation.
‒ Opening angle approx. 110° (delivery status)
= mounting distance to the wall at least 13
(350 mm).
‒ Opening angle approx. 155°
= mounting distance to the wall at least 25
(650 mm).
For an opening angle of 155°, remove both the
restrictors at the top and bottom of the hinge.
3
Position the assembly bracket
measurement stated in the image and fasten it with
2 fastening screws
(e)
bracket must be positioned at the base of the unit
and the wall such that no gap is present.
4
Fasten the transformer fixture
at the right with 2 screws
5
Attach the transformer
fixture
(j)
. The connections to both lines must point
to the left.
Note: When positioning the transformer
pushing in the appliance, do not trap the lines.
The transformer
(k)
appliance and the back wall of the cupboard.
6
Set the main switch
2
). The ideal
according to the
(c)
as shown. The assembly
(j)
in the back corner
as shown.
(e),
to the transformer
(k)
, and
(k)
is not allowed to touch the
Û
to [
] on the appliance.
(U)
" x
11
16
3
"
4
/
"
9
16

Publicidad

Tabla de contenido
loading